PM
-
3133i User
’s Manual v1.02
Last Revised: Apr. 2023 Page: 26
Copyright © ICP DAS Co., Ltd. All Rights Reserved.
E-mail: [email protected]
Modbus Module #4
-
Input Register :Power value (Float)
Parameter
name
Modbus Register
Len
Data Type
Range
Units
Comment
Modicom Format
Hex
V_a
34353-34354
0x1100-0x1101
DWord
Float
Volt
Refer to Q12
I_a
34355-34356
0x1102-0x1103
DWord
Float
Amp
kW_a
34357-34358
0x1104-0x1105
DWord
Float
kW
kvar_a
34359-34360
0x1106-0x1107
DWord
Float
kvar
kVA_a
34361-34362
0x1108-0x1109
DWord
Float
kVA
PF_a
34363-34364
0x110A-0x110B
DWord
Float
kWh_a
34365-34366
0x110C-0x110D
DWord
Float
kvarh_a
34367-34368
0x110E-0x110F
DWord
Float
kVAh_a
34369-34370
0x1110-0x1111
DWord
Float
V_b
34371-34372
0x1112-0x1113
DWord
Float
Volt
Refer to Q12
I_b
34373-34374
0x1114-0x1115
DWord
Float
Amp
kW_b
34375-34376
0x1116-0x1117
DWord
Float
kW
kvar_b
34377-34378
0x1118-0x1119
DWord
Float
kvar
kVA_b
34379-34380
0x111A-0x111B
DWord
Float
kVA
PF_b
34381-34382
0x111C-0x111D
DWord
Float
kWh_b
34383-34384
0x111E-0x111F
DWord
Float
kvarh_b
34385-34386
0x1120-0x1121
DWord
Float
kVAh_b
34387-34388
0x1122-0x1123
DWord
Float
V_c
34389-34390
0x1124-0x1125
DWord
Float
Volt
Refer to Q12
I_c
34391-34392
0x1126-0x1127
DWord
Float
Amp
kW_c
34393-34394
0x1128-0x1129
DWord
Float
kW
kvar_c
34395-34396
0x112A-0x112B
DWord
Float
kvar
kVA_c
34397-34398
0x112C-0x112D
DWord
Float
kVA
PF_c
34399-34400
0x112E-0x112F
DWord
Float
kWh_c
34401-34402
0x1130-0x1131
DWord
Float
kvarh_c
34403-34404
0x1132-0x1133
DWord
Float
kVAh_c
34405-34406
0x1134-0x1135
DWord
Float
V_avg
34407-34408
0x1136-0x1137
DWord
Float
Volt
I_avg
34409-34410
0x1138-0x1139
DWord
Float
Amp
kW_tot
34411-34412
0x113A-0x113B
DWord
Float
kW
kvar_tot
34413-34414
0x113C-0x113D
DWord
Float
kvar
kVA_tot
34415-34416
0x113E-0x113F
DWord
Float
kVA