background image

P2 

1. 

Appearance 

 

 

 

No.

 

Descriptions

 

LED panel cover.   
The  LEDs  statuses  are  shown  here. 
Loosening two screws and opening the 
cover can configure the module by the 
DIP switches and trigger button.   

The screws for LED panel cover. 

Connector protector.   
Loosening  two  screws  and  open  the 
protector can wire the CTs and voltage 
input cables into the module.   

The screws for connector protector. 

The connector for CT wiring 

The connector for voltage input wiring 

2. 

LED indicators 

 

 

 

 

 
 
 

 

 

 

 
The meanings of the LED actions are described as 
follows. 

No.

 

Descriptions 

Color 

Power indicator (PWR) 

Red 

RF data transmission indicator (Tx)  Green 

Error status indicator (Err) 

Yellow 

LED Actions 

Descriptions 

Red LED is always OFF 

No power 

Red LED is always ON 

Working power is given 

Both Green and Yellow LEDs are ON 

Module is initializing 

Both  Green  and  Yellow  flash  5  times  per 
second 

Detecting hardware errors during 
initializing. 

Green  LED  is  always  ON,  Yellow  LED  flashes 
quickly and periodically. 

Invalid  Node  ID  (Node  ID  0  is 
reserved, and can’t be used) 

Green  and  yellow  LEDs  interactively  flash  3 
times afterwards turned ON simultaneously. 

Detecting 50Hz AC frequency. The 
60Hz won’t have any indication. 

Green  and  Yellow  LEDs  are  OFF,  afterwards 
Green  LED  flashes  depended  on  the  Tx  duty 
or while receiving an RF command. 

The  module  has  finished  the 
initialization, and starts to work. 

Yellow LED flashes twice per second 

Detecting errors during operating. 

Summary of Contents for iWSN-9601 Series

Page 1: ...ries Screw driver Split Core CT 4 M4 16L Mounting Screws Model Name Split Core CTs iWSN 9601 ME IP33 160 240 360 6 iWSN 9601 PCP ME IP33 None Technical Support service icpdas com www icpdas com Resour...

Page 2: ...Error status indicator Err Yellow LED Actions Descriptions Red LED is always OFF No power Red LED is always ON Working power is given Both Green and Yellow LEDs are ON Module is initializing Both Gree...

Page 3: ...RF group ID and the PA function 3 Trigger button for forcing to transmit data once Holding it 5 seconds will reset the module The Configurations and descriptions of L Switch and R Switch are as follow...

Page 4: ...scriptions Node ID NID Up Down NID Pin NID Pin 1 2 3 4 5 1 2 3 4 5 0 16 1 17 2 18 3 19 4 20 5 21 6 22 7 23 8 24 9 25 10 26 11 27 12 28 13 29 14 30 15 31 Group ID Up Down RF Group ID Pin 6 7 0 1 2 3 PA...

Page 5: ...terminal labeled B is for connection to the CT black wire AC voltage input connector AC and AC are connected to the L phase and N phase of the single phase power supply Normally GND must be shorted t...

Page 6: ...a sub network the same RF channel and group ID The architecture might look like as the right hand side figure The iWSN 9601 series provide the IP33 rating enclosure which can effectively prevent the m...

Page 7: ...N 9601 360 ME IP33 EMS Protection EFT IEC 61000 4 4 500 V ESD IEC 61000 4 2 4 kV Contact LED Indicators Status 1 for Power 1 for Tx and 1 for Error AC Power Measurement Wiring 1P2W 1CT Loops 6 Input V...

Page 8: ...0 3 Radio Frequency 433 1000 434 6000 MHz Transmission Power 9 1 dBm Typical Transmission Distance LoS 100 m Node ID 1 31 Working Duty 1 10 30 or 60 seconds Mechanical Dimensions mm 85 x 184 x 47 W x...

Page 9: ...his manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not for any infringements...

Reviews: