To map input variables “K1” & “K2” to the input channel No. 1 & 2 of the “I-87055”, double click on the
channel 1 and then click on “Connect” .Then click on “Connect” again to connect channel 2.
By the same way, please connect “OUT01” , “OUTPUT02” to output channel 1 to 2. Then we have below
window. Click on “Save” and then exit.
IMPORTANT NOTICE
:
1. I/O Slots 0 through 7 are reserved for
REAL I/O
boards that will be used in the VP-2xW7/4xx7. You can
use slot No. 8 and above for additional functionality.
2. All of the variables with “Input” and “Output” attribute
MUST
be connected through the I/O
connection as described above for any program to be successfully compiled. Only the Input and
Output attributed variables will appear in the "I/O Connections" window. In this example we have
only 2 Boolean output variables - OUT01, OUT02 and 2 Boolean input variables – K1 & K2.