Application 4: Addressable RS-232 Controller (Three channels)
Each I-7523 module has a unique address
Each I-7523 module can support three RS-232 devices, AA, AA+1 and
AA+2
The Host PC first sends a command to all I-7523 module
The destination I-7523 module will pass the command to its local
RS-232 device 1, RS-232 device 2 or RS-232 device 3.
The I-7523 module then sends the response from the RS-232 device
back to the Host PC
COM4 port of the I-7523 module can support either 1 or 2 stop bits, so it
can support a two stop-bit device, such as the HP34401A.
The RS-232 device can be used for command (Application 1) or null
command (Application 2) type controller applications
Refer to the 7523.c file for the source code of the firmware