3 . Wiring Diagram For Different Application 

 

If users want to download users’ program, the following structure may be needed. Users 
must use the download cable (packaged with I-7188XBD-CAN) to connect the I-
7188XBD-CAN COM1 with PC available COM port. Then, use the tool, 7188xw.exe, in 
OSImage folder to download users’ program. Please refer section 4 of user manual for 
more detail information.

 

 

 

The following figure shows the wiring diagram for general application. When the COM1 
of I-7188XBD-CAN is used, sending data to COM1 will transmit the data both on RS-
232 and RS-485 port. One of the RS-232 and RS-485 port receives the data, these data 
will be obtained by COM1 of the I-7188XBD-CAN. Therefore, it is not recommend using 
both RS-232 and RS-485 functions of COM1 at the same time. If users select the RS-
232 function of COM1, the RTS1 and CTS1 pins are not always necessary. It is need to 
check if the connection target machine uses 3-line RS-232 communication or 5-line RS-
232 communication. 

 