OWNER’S MANUAL FOR iCOOL RECOVERY SYSTEMS
All iCool Lite Models from January 2013
iCoolsport.com
Page 15
SPECIFICATIONS
LITE
COMPACT
Dual Temp
COMPACT
Twin
COOLING POWER
2600 Watts
4800 Watts
5000 Watts
HEATING POWER
-
4400 Watts
-
RUN (& Max.) POWER @220Volts
4 Amps(10Amps)
7 Amps(12Amps)
7 Amps(14Amps)
RUN (& Max.) POWER @110Volts
8 Amps(20Amp)
12 Amps(22Amp)
12 Amps(26Amps)
HEAT PUMP TYPE
Rotary Compressor
Rotary Compressor
Rotary Compressor
EARTH LEAK SAFETY DEVICE
Yes 30 Milliamps
Yes 30 Milliamps
Yes 30 Milliamps
STAINLESS STEEL HEAT
ExCHANGER TANK
10 plate, silver
soldered
14 plate, silver sol-
dered
14 plate, silver sol-
dered
ROLLER BEARING WHEELS
No
Yes
Yes
STAINLESS HANDLES
Yes
Yes
Yes
AREA LIGHTING
No
Yes 10 Watts
Yes 20 Watts
HI RESOLUTION COLOUR TOUCH
SCREEN
Yes 800 x 480
Yes 800 x 480
Yes 800 x 480
WATER CIRCULATING PUMP,
Low Voltage, 100% Safe, Self Testing
15 Litres per minute
pre set
25 Litres per minute
pre set
25 Litres per minute
pre set
MAxIMUM PUMP CAPACITY
20 Litres Per Min
30 Litres Per Min
30 Litres Per Min
LOCKING MAIN POWER PLUG
3 Pin Heavy Duty
3 Pin Heavy Duty
3 Pin Heavy Duty
WEIGHT KG / POUNDS
21KG 49 Lbs
38KG 84 Lbs
40KG 88 Lbs
DIMENSIONS H. - W. - D. in mm.
240x420x300
545x475x290
545x475x290
DIMENSIONS H. - W. - D. Inches
10x16.5x11.8
21.5x18.7x11.4
21.5x18.7x11.4
IF THE STATUS BAR LIGHT ON TOP OF THE ICOOL TURNS RED WHEN YOU START THE COOLING CYCLE.
If the water temperature in the pool is already lower than the cooling temperature you set then the iCool will
automatically attempt to heat the water to match the temperature you have set. The red bar indicates activation
of the heating mode.
No Heating can occur if your model does not have the heating option.
For safety reasons the system will not change from heating mode back to cooling mode unless you re start it by
turning the main power off and back on. For cooling, you must set a temperature that is lower than the present
temperature of the water. If you need to set a temperature that is very close to or the same as the present pool
temperature start the cooling within a few seconds after starting the pump, before the system has time to read
the water temperature.