background image

OWNER’S MANUAL FOR iCOOL RECOVERY SYSTEMS

 

All iCool Lite Models from January 2013  

 

iCoolsport.com

Page 3

IMPORTANT SAFETY ADVICE 

POWER SUPPLY VOLTAGE MUST BE OBSERVED.

Your iCool Lite can only be used with the voltage marked on the machine, 

IT IS NOT MULTI VOLTAGE. 

The voltage is marked under to the main power socket. It will be either 110volts (USA) or 220volts (Europe etc)

TO ENSURE SAFE OPERATION THE POWER OUTLET YOU USE MUST HAVE A PROPER EARTH CONNECTION.

BUILT IN SAFETY SYSTEMS

Your iCool system has many safety features to protect against such things as a loss of water flow, overheating of the 

system, or any chance of the user receiving an electrical shock. If any such potentially dangerous things should occur, in 

most cases your iCool will shut itself down and a red warning screen will appear to assist you to identify and correct the 

problem. In the case of overheating, the main fan will continue to run for some time until the temperature is safely back to 

normal.  
For the safety of users, any leakage of even a small amount of electrical current will cause the system to instantly remove 

all electrical power.  

In the unlikely event that your system shuts itself down for any of these reasons, you must identify and correct the problem 

that has caused the safety systems to operate before allowing anyone to use the system. 
PLEASE TEST THE EARTH LEAKAGE SAFETY DEVICE REGULARLY 
The main power switch is also part of the electrical safety circuit that can prevents the possibility of electric shock. It is 

essential to test this safety system each time you use the iCool to make certain it is operating correctly. This is very easy 

to do and takes only a few seconds.

Turn on the main switch (blue colour) and then press the orange test button marked 

T

 just above the switch. If the safety 

system is working normally, pressing the test button will cause the main power switch to shut off instantly. 
After a successful test, reset the main switch to ON to begin normal operation.

 If pressing the test button fails to instantly 

shut off the power switch DO NOT USE THE SYSTEM  until you contact iCool for advice. Failures of this system are very rare.

OBTAINING THE CORRECT FLOW OF WATER

OCCASIONALLY YOU MAY ExPERIENCE SOME DIFFICULTY GETTING THE WATER TO FLOW CORRECTLY THROUGH 

YOUR ICOOL DUE TO TRAPPED AIR IN THE SYSTEM OR THE HOSES. 

As you gain experience using an ice bath system you will learn to overcome this quickly and easily.
ABOUT PUMPS. Water flow through your iCool Lite is produced by a high-quality long life circulating type pump that is fitted 

into the lower pool connecting hose. For total safety it operates at 12 volts DC and is completely water proof. 
Circulating type pumps are not self priming, they can lift and move water reliably for many thousands of hours, but due to 

the long life design they can not provide suction to begin the flow if there is air trapped anywhere in the pump or hoses. 

Self priming type pumps are not used because they are generally not as reliable over long periods and not suitable for this 

type of system. 
Like all circulating pumps, the pu   mp in your iCool can not begin to operate unless it is has a head of water above the pump 

and any air tapped in the system is removed. Therefore, before you start, the water in the pool must be above the pump. 

There must be no air trapped in the supply hose and no part of the hose from the pool to the cooling system can be above 

the level of the water because this traps air which can prevent water flow from starting.
There are several easy ways to clear trapped air in the system. For example, by touching the PUMP ON-OFF button 3 or 

4 times so that the pump is off for about 5 to 10 seconds each time. The surge when the pump starts can often clear the 

trapped air, but it may take a few times if there is a lot of trapped air.

If you still do not have a good flow of water

 

try detaching the water hose from the bottom inlet fitting on the Lite. 

This is the hose that has the pump in it. Now turn on the pump until a good clear flow of water comes out of the hose, then 

quickly snap it back into position on the iCool and lock it. This is the most effective way to clear an air blockage so that 

water can flow normally.

YOU ONLY NEED TO BLEED THE SYSTEM ONCE FOR EACH SET UP

. Once primed of air, (and until it is emptied or moved), 

the system will remain primed until and water will normally flow instantly each time you start the pump

NEVER OPERATE THE PUMP WITHOUT WATER FLOWING

 Water pumps can not operate for long periods without water 

because the water provides the lubrication to the bearings. To prevent damage, your iCool system will stop the pump if 

water is not flowing properly for more than 2 minutes.  When this happens a warning screen will normally appear to explain 

to you how to correct the problem. 

Summary of Contents for iCool Lite

Page 1: ...several attempts it will shut down and warn the user With optional low cost attachments the new pwater pump system allows you to use your Lite with virtually any small pool spa or bath tub The new pump system operates from very safe low voltage for total safety WARNING Do not use this machine with Chlorine Bromide or Salt These chemicals are very corrosive and can damage the stainless steel heat e...

Page 2: ...old can be quickly lost Good insulation reduces these losses Good insulation will result in much faster cooling and save a lot of electricity HOLDING THE SET TEMPERATURE In normal conditions once your pool reaches your set temperature your iCool Lite has been designed to have enough cooling power to continue to hold that temperature even if several athletes are using the pool NEVER USE CORROSIVE C...

Page 3: ...TRAPPED AIR IN THE SYSTEM OR THE HOSES As you gain experience using an ice bath system you will learn to overcome this quickly and easily ABOUT PUMPS Water flow through your iCool Lite is produced by a high quality long life circulating type pump that is fitted into the lower pool connecting hose For total safety it operates at 12 volts DC and is completely water proof Circulating type pumps are n...

Page 4: ...l STEP 1 Before you fill the pool you must connect the PUMP MODULE and the 2 hoses provided to the inlet and outlet fittings on the Lite unit ICool hoses have convenient snap fittings that are very quick and easy to use The large hose with the circulating pump in line connects from the bottom of the pool to the bottom inlet fitting on the Lite SCREW THE BIGGER OF THE 2 CONNECTION HOSES PROVIDED TO...

Page 5: ...s takes it very close to the temperature that water freezes solid Following international safety standards your iCool will not accept water temperature settings below 6ºC or 42ºF as this would put athletes using the system unattended at risk of hypothermia However the iCool is easily powerful enough to freeze the water inside the system itself and if this happens the safety screen above will appea...

Page 6: ...E iCOOL LOGO WILL FLASH WHITE The iCool Logo is the system STATUS BAR it changes colour or flashes to give a clear indication of each function While the software is loading it will flash white the welcome screen shown above will appear and then a black screen appears for about 15 seconds while the computers test the safety systems When your personal logo screen see examples below appears it will s...

Page 7: ... water does not flow smoothly within a minute please check that the hose from the bottom of the pool is flat on the floor and no part of it is higher than the top of the water Check that the water in the pool is higher than the pump If this does not correct the problem the system will sound an alarm and a red warning screen will appear with information about how to correct the water flow problem S...

Page 8: ...e reading exceeds this you need to move the system to a cooler area or improve the air flow The PRESET TEMPERATURE WINDOW always shows your selected temperature This is the temperature the water will be automatically cooled or heated to and maintained at CHANGING THE TEMPERATURE SETTING You can change your preset temperature at any time by touching the CHANGE SETTING BUTTON this will take you to t...

Page 9: ...so there usually no need to use this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the sound level from the screen MAIN COOLING FAN SPEED This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to con...

Page 10: ...ed athlete using the pool your system will not allow you to set temperatures below 5 C 40 F If the model you are using is the contrast model which also provides heating for contrast therapy you cannot set the temperature above 45 C 112 F because of the risk of scalding These temperature limits have been set after wide consultation with the sporting industry around the world There are no demonstrat...

Page 11: ... does perfectly The session timer is set up from the main TIME SETTING SCREEN by touching the SET COUNTDOWN button The numbers on the setting screen in the bottom right hand corner will begin to flash and you can use the left right and up down arrows to change the time in minutes and seconds Once you have set the time you want your athletes to remain in the bath touching the DISPLAY COUNTDOWN FULL...

Page 12: ...elp system Detailed and well illustrated helpful information on every important subject to do with the operation of your iCool is available from almost any screen simply by touching the help button Touching any help button will take you to the screen illustrated on the right The screen has eight menu buttons covering all of the important topics you are ever likely to need assistance with When you ...

Page 13: ... run screen for more than 10 seconds you can only lock from this main screen A picture of a lock will appear While ever this lock is visible it is not possible to make any inputs or to change screens To unlock the system and returned to normal repeat the procedure Touch and hold the iCool icon for more than 10 seconds The lock will disappear and all functions will return to normal You can flip for...

Page 14: ...p it sometimes occurs that the water flow monitoring system may be too sensitive and will stop the pump because it appears that water is not flowing properly We allow this to be over ridden if it becomes troublesome Instructions on how to do this will appear on the screen automatically if this happens It must be remembered of course that if you disarm this system the pump is no longer protected fr...

Page 15: ...0 Litres Per Min 30 Litres Per Min 30 Litres Per Min LOCKING MAIN POWER PLUG 3 Pin Heavy Duty 3 Pin Heavy Duty 3 Pin Heavy Duty WEIGHT KG POUNDS 21KG 49 Lbs 38KG 84 Lbs 40KG 88 Lbs DIMENSIONS H W D in mm 240x420x300 545x475x290 545x475x290 DIMENSIONS H W D Inches 10x16 5x11 8 21 5x18 7x11 4 21 5x18 7x11 4 IF THE STATUS BAR LIGHT ON TOP OF THE ICOOL TURNS RED WHEN YOU START THE COOLING CYCLE If the...

Page 16: ...ivered in your country due to local conditions or regulations or other factors Also certain specifications may change due to ongoing research and development because we are constantly improving our products We welcome your feedback and suggestions and we offer support for general enquiries and information for specific countries on our website at Thank you for choosing iCool the world s most popula...

Reviews: