39
4. Servicing
Turn the appliance OFF and isolate the gas supply. Ensure the appliance is fully cold before attempting to start
servicing the appliance. No liability can be accepted by Heat Design for injury caused by burning or scolding by a
hot appliance.
A suggested procedure for servicing is listed below.
A. Lay out dust sheet on flooring, mask off any special fireplace materials.
B. Remove Side Window Trims
C. Remove Bottom Window Trim
D. Remove Window Assembly
E. Carefully remove the Ceramic components (including Embers) or Gravels
F. Use a Vacuum cleaner to clean the top of the burners and grate
G. Remove Grate
H. Remove all 3 Burner Top assemblies, there are 3 M6 flange bolts holding each in
I. Using a vacuum cleaner, fully clean both Burner Top plates.
J. With the Burner Tops now removed, the Pilot and the heads of the injectors are clearly visible. Use the
vacuum cleaner and a soft brush to clean the pilot assembly and both Injectors. Never modify or bend the
Thermocouple
K. Replace the burner top assemblies and fix in with the fixings
L. Turn on the gas supply and check for leaks, check the burners and Pilot for good condition and operation
M. Replace Grate
N. Replace the Firebed arrangements
O. Replace Window Assembly and Trims
P. Check the flue system and terminal, making sure that the terminal vent is fully clear
Q. Light the appliance and test setting pressures
R. Check the safe operation of the appliance.
4.1 Cleaning the Ceramics
Remove the ceramics as detailed in A - E above.
Gently clean the ceramics in the open air, using a soft brush and a vacuum cleaner. Where necessary replace
damaged components only with genuine Heat Design specified parts. Seal any scrap ceramics in plastic bags and
dispose at proper refuse sites. When using a vacuum cleaner, it is recommended that one with a HEPA filtering
system is used.
Re-fit the Firebed arrangement, re-seal the appliance and check the safe operation of the appliance.
4.2 Servicing the Burners
Remove the Burner Top Assemblies as detailed in A - H above.
The pilot is now clearly visible, the pilot, including the Thermocouple, can be replaced/serviced by removing
raising the pilot assembly from its mounting. This is done by removing the two screws on the surface of the
pilot. The fittings on the under-side of the pilot can be un-done using a 10mm spanner where appropriate.
To access the Main Burner Injectors, the Burner base units must be removed. This is done by removing the six
bolts (M6, 10mm spanner) holding the burner in. With these six bolts removed, the Burner base can be raised up
through the Firebox, and the Injectors can be easily accessed.
When replacing any parts use only original Heat Design specified parts.
Summary of Contents for 1100 Front
Page 3: ...3 Iconic 1100 Bay ICONIC1100 3S ...
Page 4: ...IE GB 4 Iconic 1100 Corner Left Right IC1100 CL CR ...
Page 5: ...5 Iconic 1100 Room Divider ICONIC1100 RD ...
Page 6: ...IE GB 6 Iconic 1100 See Through IC1100 ST ...
Page 19: ...19 3 3 3 Mantel Clearances 3 3 3 a Combustible Mantel Side view ...
Page 20: ...IE GB 20 ...
Page 21: ...21 3 3 3 b Combustible Mantel Side Wall Top view ...
Page 25: ...25 Horizontal Wall Vent Termination Category 1 for 200 130 type C11 ...
Page 27: ...27 Typical Installations ...
Page 32: ...IE GB 32 ...
Page 34: ...IE GB 34 3 5 5 Iconic 1100 Pebble Effect ...
Page 43: ...43 Annex 1 ...
Page 44: ...IE GB 44 ...
Page 45: ...45 ...
Page 46: ...IE GB 46 ...
Page 47: ...47 ...