3.6 Commissioning the Appliance
3.6.1 Pilot Ignition Check
1. Ignite the pilot light as described in the User Instructions
2. Check that the pilot flame stays alight
3. Extinguish the pilot light
3.6.2 Main Burner Check
1. Ignite the pilot light as described in the User Instructions
2. Turn on the main burner as described in the User Instructions
3. Check that the pilot smoothly cross-lights to the main burner and that the main burner and pilot stay alight
4. Check the operation of the "effect" burners as described in the User Instructions
5. Extinguish the appliance fully
3.6.3 Pressure Check
The appliance is preset to give the correct heat inputs as listed in the technical details. No further adjustment
is necessary. Always check the inlet pressure and burner pressure.
1. Turn off the gas valve on the appliance
2. Release the screw on the Inlet Pressure test point on the gas valve and connect a pressure guage Manometer
3. Check that the measured pressure is as the prescribed supply pressure
4. Perform the test when the appliance is burning on full (inc. "effect" burners) and with only the pilot alight
5. If the pressure is low, check the gas supply pipes are to a correct sizing
6. If the pressure is too high (more than 5 mbar over) the appliance may be installed, but the gas supply
company should be contacted
7. Release the screw on the Burner Pressure test point on the gas valve and connect a manometer
8. Check that the measured pressure is as detailed in the Technical details
9. The measured value should be /- 10% of the described value. If this is not the case, please contact
the supplier.
Note: After checking the pressures and removing the manometers, the screws in the Pressure Test points must
be closed, and the system must be checked for gas-tightness.
Summary of Contents for 1100 Front
Page 3: ...3 Iconic 1100 Bay ICONIC1100 3S ...
Page 4: ...IE GB 4 Iconic 1100 Corner Left Right IC1100 CL CR ...
Page 5: ...5 Iconic 1100 Room Divider ICONIC1100 RD ...
Page 6: ...IE GB 6 Iconic 1100 See Through IC1100 ST ...
Page 19: ...19 3 3 3 Mantel Clearances 3 3 3 a Combustible Mantel Side view ...
Page 20: ...IE GB 20 ...
Page 21: ...21 3 3 3 b Combustible Mantel Side Wall Top view ...
Page 25: ...25 Horizontal Wall Vent Termination Category 1 for 200 130 type C11 ...
Page 27: ...27 Typical Installations ...
Page 32: ...IE GB 32 ...
Page 34: ...IE GB 34 3 5 5 Iconic 1100 Pebble Effect ...
Page 43: ...43 Annex 1 ...
Page 44: ...IE GB 44 ...
Page 45: ...45 ...
Page 46: ...IE GB 46 ...
Page 47: ...47 ...