26
3.4.7 Vertical Roof Vent Termination C
31
Flue sizing:
Iconic 1100 : Ø130/200 (Ø5”/8”) Connector on Appliance.
Ø130/200 (Ø5”/8”) Maybe used Throughout, Alternatively,
Ø100/150 (Ø4”/6
⅝
”) Reducer may be used, so that Ø100/150 (Ø4”/6
⅝
”) flue
can be used thereafter.
Flue Terminal: Ø130/200 (Ø5”/8”) Roof Terminal
Ø100/150 (Ø4”/6
⅝
”) Roof Terminal
Minimum Vertical Flue Height: 0.5m
Flue Restrictors to be fitted,
Ø130/200 (Ø5”/8”):
Iconic 1100
Vertical Rise <1m No Restrictor
Vertical Rise 1-2m 35mm Restrictor
Vertical Rise > 2m 60mm Restrictor