Rotor Pin | Paddle Replacement

04

05

06

01

02

03

08

09

07

Line up Pin with Rotor Hole

Spot Point

Small Pin

Avoid Damage to

the Plastic outside

Ensure Holes

are Aligned

GENTLY

 tap Wedge with

Mallet or Hammer

GENTLY tap Rotor Pin
with Mallet or Hammer

50% Out

 Pin

Tap until Rotor is 50% Out

Pull out Rotor Pin

Push in Rotor Pin
approx. 50%

Congratulation!

Replacement Procedure

Complete!

Paddle

Insert New

Paddle in

Flow Meter

www.iconprocon.com | [email protected] | 905.469.9283

12

Battery Operated 

-

 Paddle Wheel Flow Meter

TIB SERIES

Pull Out Rotor Pin

Entire Way Until

Paddle Wheel

is loose

Summary of Contents for TRUFLO TIB Series

Page 1: ...Battery Operated Flow Meter TIB SERIES Operating Manual www iconprocon com sales iconprocon com 905 469 9283 Battery Operated Paddle Wheel Flow Meter TIB SERIES 330 TIB Series...

Page 2: ...ow Rates K Factors Installation Information Sensor Installation Correction Sensor Position Battery Replacement V Series Battery Replacement H Series Rotor Pin Paddle Replacement Dimensions Warranty Re...

Page 3: ...pressure proof pressure wetted material requirements media compatibility operating temperature vibration pulsation desired accuracy and any other gauge component related to the service application in...

Page 4: ...PVC 60 C PP 80 C PF 100 C Protection Class IP 65 General Purpose Approval CE RoHS Optional Superhydrophobic Design Contoured Flow Profile Reduced Turbulence Reduced Friction 78 Less Drag than Old Flat...

Page 5: ...e Life Display Functions Pressure vs Temperature Ceramic Shaft Bearings High Chemical Resistance Long Life 40 years m s Self Cleaning Design Bushing 2 Shaft Contoured Paddle 220 220 220 220 220 220 22...

Page 6: ...ife Press Key 1 9999 Light On Step 5 Press Key 1 9999 Flow Alarm Delay Step 6 Press Key Programming Totalizer Password Reset Totalizer Step 7 rESEt 0 Flow Totalizer Reset Disabled rESEt 1 Default Flow...

Page 7: ...CPVC SCH80 Tee Fitting Unit inch Size DN Id 2 2 3 4 6 8 10 12 14 16 20 24 50 65 80 100 150 200 250 300 350 400 500 600 1 9 2 3 2 9 3 8 5 7 7 0 9 5 11 3 12 4 15 1 19 0 21 0 81 65 54 43 34 96 19 80 9 1...

Page 8: ...licone Inside of Insertion Fitting Locating Pin Notch 1 NPT Fig 5 Retention Cap Flow Process Pipe Sensor Blade Ensure Tabis Parallel to Flow Direction Fig 4 TIB Series OP1 FTM OP2 GPM 01 02 03 Engage...

Page 9: ...if NO Air Bubbles Present Preferred Installation if Sediment or Air Bubbles may be Present TI Series Flow Meters measure liquid media only There should be no air bubbles and the pipe must always remai...

Page 10: ...Screw Driver into Slot Remove Cover Remove 1st Battery Remove Screws Carefully Remove Display Module Remove Battery Pack Replace Battery Pack Reassemble www iconprocon com sales iconprocon com 905 469...

Page 11: ...o Slot Remove Cover Remove 1st Battery Remove Screws Carefully Remove Display Module Remove Battery Pack Replace Battery Pack Reassemble www iconprocon com sales iconprocon com 905 469 9283 11 Battery...

Page 12: ...let or Hammer GENTLY tap Rotor Pin with Mallet or Hammer 50 Out Pin Tap until Rotor is 50 Out Pull out Rotor Pin Push in Rotor Pin approx 50 Congratulation Replacement Procedure Complete Paddle Insert...

Page 13: ...Paddle Wheel Flow Meter TIB SERIES 2 54 in 64 5 mm TIB Series 4 96 in 126 1 mm 3 90 in 99 1 mm TIB Series 3 96 in 100 7 mm 4 36 in 110 7 mm 2 66 in 67 5 mm 4 36 in 110 7 mm 2 66 in 67 5 mm 3 62 in 91...

Page 14: ...ectrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Icon Process Controls Ltd have at...

Page 15: ......

Reviews: