ETTINGS
You can set different parameters through 2 encoders allowing 16 positions each (see Tune Up procedure for further
information).
Figure 2 : front face
Figure 3 : encoders & LEDs
Figure 4 : front face without/with sticker
3 PARAMETERS DESCRIPTION
See tune up procedure for specific parameters configuration.
3.1
S
ENSITIVITY
The factory setting fulfills the requirements of the majority of the installations. If the position or the size of the
detection area is not satisfactory, change first the position of the radar (tilt angle and/or height of installation).
3.2
S
ELF
-
MONITORING
The self-monitoring monitors the following parts of the hardware:
-
Micro-wave device (VCO)
-
Mixers
-
Analogic format channel
-
Analogic/digital converter
-
Micro-processor oscillator
-
Code running
When a failure is detected, the relays are permanently actuated and the LEDs flashing show an error code (see
Tune up procedure for further information). The radar is reset after 1 hour.
3.3
RF
CHANNEL
This parameter allows to shift the radar’s frequency. If two units face each other, they must be put on different
channels, so they don’t interfere with each other.
Once you have set the
requested radar parameters,
place the sticker on the front
face to guarantee its water
tightness.
ATTENTION:
manufacturer’s
warranty does not cover
radars without sticker!