background image

6

REMOTE CONTROL

Remote control (CI-V) information

 

D

Command formats

 

Operating frequency

Command: 00, 03, 05

 

Offset frequency setting

Command: 0C, 0D

 

Operating mode

Command: 01, 04, 06

Receive mode

1

Operating mode

2

Filter setting

FM

05

01

FM-N

05

02

DV

17

01

AM

02

01

AM-N

02

02

X

X

X

q

w

X

e

X

X

1 kHz digit

100 Hz digit

100 kHz digit

10 kHz digit

10 MHz digit

1 MHz digit

1

0

X

X

X

X

2

3

X

4

5

X

X

X

0

10 Hz digit: 0

, 5

(Depends on the 100 Hz digit�)

1 Hz digit: 

(fixed)

 

1 kHz digit: 0

 ~

 9

100 Hz digit: 0, 2, 5, 7

100 kHz digit: 0

 ~

 9

10 kHz digit: 0

 ~

 9

10 MHz digit: 0

 ~

 9

1 MHz digit: 0

 ~

 9

1 GHz digit: 

(fixed)

100 MHz digit: 0

 ~

 4

q

w

X

X

X

X

 

L

When the 100 Hz digit is 2 or 7, the 10 Hz digit is 

fixed to 5 and is fixed to 0 otherwise�

 

 AF gain level setting

Command: 14 01

 

Squelch level setting

Command: 14 03

 

VOX gain setting

Command: 14 16

 

RF power setting

Command: 14 0A

 

MIC gain (External) setting

Command: 14 0B

VOL0

VOL1

VOL2

VOL3

0000 ~ 0005 0006 ~ 0012 0013 ~ 0018 0019 ~ 0025

VOL4

VOL5

VOL6

VOL7

0026 ~ 0031 0032 ~ 0037 0038 ~ 0044 0045 ~ 0050

VOL8

VOL9

VOL10

VOL11

0051 ~ 0057 0058 ~ 0063 0064 ~ 0069 0070 ~ 0076

VOL12

VOL13

VOL14

VOL15

0077 ~ 0082 0083 ~ 0089 0090 ~ 0095 0096 ~ 0101

VOL16

VOL17

VOL18

VOL19

0102 ~ 0108 0109 ~ 0114 0115 ~ 0121 0122 ~ 0127

VOL20

VOL21

VOL22

VOL23

0128 ~ 0133 0134 ~ 0140 0141 ~ 0146 0147 ~ 0153

VOL24

VOL25

VOL26

VOL27

0154 ~ 0159 0160 ~ 0165 0166 ~ 0172 0173 ~ 0178

VOL28

VOL29

VOL30

VOL31

0179 ~ 0185 0186 ~ 0191 0192 ~ 0197 0198 ~ 0204

VOL32

VOL33

VOL34

VOL35

0205 ~ 0210 0211 ~ 0217 0218 ~ 0223 0224 ~ 0229

VOL36

VOL37

VOL38

VOL39

0230 ~ 0236 0237 ~ 0242 0243 ~ 0249 0250 ~ 0255

OPEN*

AUTO

LEVEL1

LEVEL2

0000 ~ 0022 0023 ~ 0046 0047 ~ 0069 0070 ~ 0092

LEVEL3

LEVEL4

LEVEL5

LEVEL6

0093 ~ 0115 0116 ~ 0139 0140 ~ 0162 0163 ~ 0185

LEVEL7

LEVEL8

LEVEL9

0186 ~ 0208 0209 ~ 0232 0233 ~ 0255

*Except the DV mode�

OFF

1

2

3

0000 ~ 0022 0023 ~ 0046 0047 ~ 0069 0070 ~ 0092

4

5

6

7

0093 ~ 0115 0116 ~ 0139 0140 ~ 0162 0163 ~ 0185

8

9

10

0186 ~ 0208 0209 ~ 0232 0233 ~ 0255

S-Low

Low1

Low2

Mid

0000 ~ 0050 0051 ~ 0101 0102 ~ 0153 0154 ~ 0204

High

0205 ~ 0255

1

2

3

4

0000 ~ 0063 0064 ~ 0127 0128 ~ 0191 0192 ~ 0255

Summary of Contents for ID-52A

Page 1: ...CI V REFERENCE GUIDE VHF UHF TRANSCEIVER ID 52A ID 52E...

Page 2: ...h level setting 6 RF power setting 6 MIC gain External setting 6 VOX gain setting 6 Repeater tone tone squelch frequency setting 7 DTCS code and polarity setting 7 Digital code squelch setting 7 DV MY...

Page 3: ...sceive is set to ON the same change as your transceiver is automatically set on other connected transceivers or receivers and vice versa L LSee page 3 about how to connect a PC to the SP jack through...

Page 4: ...h the SP jack is not guaranteed See the CT 17 instruction manual for details of remotely controlling transceivers and receivers ID 52A E ct 17 Power supply 9 V 15 V DC RS 232C cable PC 2 conductor 3 5...

Page 5: ...F 10 10 dB 375 479 MHz 30 30 dB 108 374 995 MHz 14 01 See p 6 Send read the audio level 03 See p 6 Send read the squelch level 0A See p 6 Send read the RF power setting 0B See p 6 Send read MIC gain E...

Page 6: ...01 ON 01 See p 9 Output DV RX status for transceive 02 See p 9 Read Auto DV RX status Command Sub Data Description 20 03 00 00 01 Send read the Auto DV RX GPS D PRS data output 00 OFF 01 ON 01 See p 9...

Page 7: ...L1 VOL2 VOL3 0000 0005 0006 0012 0013 0018 0019 0025 VOL4 VOL5 VOL6 VOL7 0026 0031 0032 0037 0038 0044 0045 0050 VOL8 VOL9 VOL10 VOL11 0051 0057 0058 0063 0064 0069 0070 0076 VOL12 VOL13 VOL14 VOL15 0...

Page 8: ...nual for the tone frequency list Refer to the Advanced manual for the DTCS code list DV MY call sign setting Command 1F 00 Set your own call sign and note of up to 12 characters See Character s code o...

Page 9: ...eive no reply 0 0 1 Repeater disabled 0 0 0 NULL 3 10 Call sign of the caller station 8 characters fixed 11 14 Note of the caller station 4 characters fixed 15 22 Call sign of the called station 8 cha...

Page 10: ...ation L LIf it was a call through a gateway and the internet this item displays the gateway call sign of the repeater you received the call from RXRPT2 Call sign of the repeater you received the call...

Page 11: ...s 00h EFh 52 Type 1 Live 0 Killed L LThe item that is not contained the received data is filled with FF L LFF No signal has been received since the power was turned ON GPS D PRS data Position Command...

Page 12: ...32 0 3 X X X X 1 9 X X 33 X X X X 34 35 X X X X X X X X 39 40 41 42 X X X X 36 38 X X X X 43 44 X X X X 45 46 X X X X 47 49 Data number GPS D PRS data Item Command 20 03 0102 20 03 0202 1 9 Call sign...

Page 13: ...9 space 10 52 Message Up to 43 ASCII characters 00h EFh L LFF No signal has been received since the power was turned ON DV TX data Command 22 00 1 30 X X X X Variable length 1 30 TX data Up to 30 Byte...

Page 14: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A7608 6EX 2020 Icom Inc Dec 2020...

Reviews: