5 - 5
ADJUSTMENT
DISPLAYED ITEM
OPERATION
VALUE
S-METER
(Preparation)
1
–
• Connect an SSG to the antenna connector and set it
as;
Modulation : 1 kHz
–
-MF band-
(FM:S3 level)
2
[FS3]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 3.5 kHz (FM)
Level
: 0 dBµ
2) Push [ENT MW] key.
(Automatic
adjustment)
-MF band-
(WFM:S0 level)
3
[WS0]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 52.5 kHz (WFM)
Level
: 3 dBµ
2) Push [ENT MW] key.
-14 MHz band-
(FM:S3 level)
4
[FS3]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 3.5 kHz (FM)
Level
: –5 dBµ
2) Push [ENT MW] key.
-14 MHz band-
(WFM:S0 level)
5
[WS0]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 52.5 kHz (WFM)
Level
: –2 dBµ
2) Push [ENT MW] key.
-51 MHz band-
(FM:S3 level)
6
[FS3]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 3.5 kHz (FM)
Level
: –5 dBµ
2) Push [ENT MW] key.
-51 MHz band-
(WFM:S0 level)
7
[WS0]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 52.5 kHz (WFM)
Level
: –2 dBµ
2) Push [ENT MW] key.
-83 MHz band-
(FM:S3 level)
8
[FS3]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 3.5 kHz (FM)
Level
: –5 dBµ
2) Push [ENT MW] key.
-145 MHz band-
(WFM:S0 level)
9
[WS0]
1) Set the SSG as;
Frequency : (Displayed on the function display)
Deviation
: 52.5 kHz (WFM)
Level
: –2 dBµ
2) Push [ENT MW] key.
STANDARD SIGNAL GENERATOR
(0.3–1500 MHz)
COMMON SETTING;
Modulation : 1 kHz
Deviation
: 3.5 kHz (FM)
: 52.5 kHz (WFM)
Summary of Contents for IC-RX7
Page 1: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 8 VOLTAGE DIAGRAM 10 Feb 2010...
Page 16: ...SERVICE MANUAL ADDENDUM CONTENTS REPLACEMENT PAGE 6 1 PARTS LIST 1 VOLTAGE DIAGRAM 8 Feb 2009...
Page 30: ...S 14510XZ C1 Aug 2008 WIDEBAND RECEIVER...
Page 64: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 14510XZ C1 2008 Icom Inc...