27
7
SCANS
■
Priority watch operation
Priority watch checks for signals on a frequency every
5 sec. while operating on a VFO frequency.
q
Select memory mode with [V/M].
w
Select the desired memory channel to be watched
with [UP
Y
] or [
Z
DN].
e
Select VFO mode.
r
Set [RF/SQL] closed.
• If the [RF/SQL] control function is set as RF control, the
squelch always opens. See pgs. 14, 30 for details.
t
Push [SCAN] for 2 sec. to start priority watch.
• “SCAN” appears.
y
When a signal is received on a watch channel, the
function display shows the watch channel and
“SCAN” blinks.
u
To cancel the watch, push [SCAN].
USB
S1
3
5
7
9
20
40
60dB
AGC
ANT 1
SCAN
V F O
USB
S1
3
5
7
9
20
40
60dB
AGC
ANT 1
SCAN
R X
MEMO
■
Auto memory write scan
Auto memory write scan operates in the same way as
programmed scan. However, when a signal is re-
ceived, the received frequency is automatically writ-
ten into memory channels (80 to 99).
When the auto memory write scan starts, the pre-
viously written memory channels (80 to 99) are
cleared.
q
Select VFO mode with [V/M].
w
Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
e
Set [RF/SQL] closed.
• If the [RF/SQL] control function is set as RF control, the
squelch always opens. See pgs. 14, 30 for details.
r
Push [SCAN] to start the programmed scan.
• “SCAN” appears while scanning.
• If the same frequencies are programmed into the scan
edge memory channel P1 and P2, programmed scan
does not start.
t
Push [MW] to start the auto memory write scan.
• “80” blinks when auto memory write scan starts.
y
When the scan detects a signal, the frequency is
programmed into a memory channel (80 to 99),
starting from channel 80.
u
To cancel the scan, push [SCAN].
80
81
82
83
84
•
•
•
98
99
14.456.00
14.567.00
14.678.00
14.890.00
14.050.00
--------------
--------------
USB
R X
S1
3
5
7
9
20
40
60dB
AGC
ANT 1
SCAN
V F O
BLANK
BLANK