17
7
CONNECTIONS AND INSTALLATION
■
Attaching 2 remote controllers
Controller
Controller
DC 13.6 V
DC 13.6 V
DC 13.6 V
IC-M710RT
main unit
D
Set ID number
The ID numbers for each remote controller must be set
properly for the intercom function to operate (see
right).
➀
While pushing [FUNC] + [–], push [POWER].
• Channels 1 to 160 (maximum) are programmable.
➁
Rotate the channel selector to select the desired
unit ID number if desired.
• Default ID’s are No. 1 for the supplied remote controller
and No. 2 for an optional remote controller.
➂
Push [POWER] turn the power OFF.
D
Intercom operation
The intercom function allows you to communicate be-
tween two remote controllers.
➀
Push [FUNC] and then push [SPEAKER] to turn the
intercom function ON.
• “INCOM” blinks and beeps are emitted; the blinking con-
tinues until the intercom function is cancelled.
• Push [FUNC] to cancel the intercom function.
➁
Push and hold the [PTT] switch on the microphone
and speak into the microphone at a normal voice
level.
• The display stops blinking and the ID number of the re-
mote controller being used to transmit appears on both
remote controller displays.
• When no ID appears, operators at either remote con-
troller are free to transmit.
• When neither remote controller is used to transmit for 30
sec. the intercom function is automatically cancelled.
➂
Push [FUNC] to end intercom operation.
IC-M710RT.qxd 02.1.9 9:03 Page 17