background image

 

Caution

D

 Battery caution

•  

R

 

DANGER! NEVER

 short terminals (or charging termi-

nals) of the battery pack. Also, current may flow into nearby 
metal objects such as a key, so be careful when placing the 
battery packs (or the radio) in handbags, etc. Simply car-
rying with or placing near metal objects such as a key, etc. 
may cause shorting. This may damage not only the battery 
pack, but also the radio.

•  

R

 

DANGER! DO NOT

 hammer or otherwise impact the 

battery pack. Do not use the battery pack if it has been 
severely impacted or dropped, or if it has been subjected 
to heavy pressure. The damage may not be visible on the 
outside of the case. Even if the surface of the battery pack 
does not show cracks or any other damage, the cells inside 
may rupture or catch fire.

•  

R

 

DANGER! NEVER

 use or leave the battery pack in 

areas with temperatures above +60˚C (+140˚F). High tem-
perature buildup in the battery pack, such as could occur 
near fires or stoves, inside a sun heated car, or in direct 
sunlight for long periods of time may cause the battery 
pack to rupture or catch fire. Excessive temperatures may 
also degrade performance or shorten battery life.

•  

R

 DANGER! DO NOT

 expose the battery pack to rain, 

snow, seawater, or any other liquids. Do not charge or use 
a wet battery pack. If the battery pack gets wet, be sure to 
wipe it dry before using.

•  

R

 

DANGER! KEEP

 the battery pack away from fire. Fire or 

heat may cause them to rupture or explode. Dispose of an 
used battery pack in accordance with local regulations.

•  

R

 

DANGER! NEVER

 solder the battery pack terminals, or 

modify the battery pack. This may generate heat in the battery, 
and the battery pack may burst, emit smoke or catch fire.

•  

R

 

DANGER!

 Use the battery pack only with the radio for 

which it is specified. Never use a battery pack with any 
other equipment, or for any purpose that is not specified 
in this sheet.

•  

R

 

DANGER!

 If fluid from inside the battery pack gets in 

your eyes, blindness can result. Rinse your eyes with clean 
water, without rubbing them, and see a doctor immediately.

•  

R

 

WARNING!

 Immediately stop using the battery pack if 

it emits an abnormal odor, heats up, or is discolored or de-
formed. If any of these conditions occur, contact your Icom 
dealer or distributor.

17

4

BATTERY CHARGING

•  Misuse of Li-ion batteries may result in the following haz-

ards: smoke, fire, or the battery pack may rupture. Mis-
use can also cause damage to the battery pack or degra-
dation of battery performance.

•  Prior to using the battery pack for the first time, or af-

ter not using it for a long time, you must fully charge the 
pack. Otherwise, the transceiver may not turn ON.

Summary of Contents for IC-F9011

Page 1: ...INSTRUCTION MANUAL UHF P25 TRUNKING HANDHELD TRANSCEIVERS iF9011 series The photo shows the 10 key type VHF transceiver iF9023 series iF9021 series VHF P25 TRUNKING HANDHELD TRANSCEIVERS...

Page 2: ...consult with your dealer or sales representative for details EXPLICIT DEFINITIONS WORD DEFINITION RDANGER Personal death serious injury or an explo sion may occur RWARNING Personal injury fire hazard...

Page 3: ...ent from that to which the receiver is connected Consult the dealer or an experienced radio TV techni cian for help CAUTION Changes or modifications to this transceiver not expressly approved by Icom...

Page 4: ...in serious damage to the radio DO NOT push PTT when you do not actually intend to transmit DO NOT operate or place the radio in direct sunlight or in areas with temperatures below 20 C 4 F or above 60...

Page 5: ...t panel 3 Function display Simple 10 key types only 5 Programmable function keys 6 3 BASIC OPERATION 12 16 Turning power ON 12 Channel selection 12 Receiving and transmitting 13 User set mode 14 Clock...

Page 6: ...e the battery pack on the back of the transceiver in the direc tion of the arrow q then lock it with the battery release button Slide the battery pack until the battery release button makes a click so...

Page 7: ...row w q w D Connector cover Attach the connector cover when the optional equipment is not used To attach the connector cover q Insert the connector cover into the multi connector w Tighten the screw C...

Page 8: ...ICATOR Lights green while receiving a signal or when the squelch is open Lights red while transmitting The LED indicator indicates some information Non display type only p 16 r DEALER PROGRAMMABLE ABC...

Page 9: ...types only Desired function can be programmed independently by your dealer p 6 0 APP KEY APP Simple 10 key types only Desired function can be programmed by your dealer p 6 1 10 KEYPAD 10 key type onl...

Page 10: ...ted Analog mode operation only t SCRAMBLER INDICATOR Appears when the voice scrambler or encryption function is activated y BELL INDICATOR Appears blinks when the matched signal is received ac cording...

Page 11: ...d switches EMR Side1 Side2 Side3 I II III APP HOME ABC switch and Toggle switch Simple 10 key types only Consult your Icom dealer or system operator for details con cerning your transceiver s programm...

Page 12: ...iod Depending on the pre setting pushing and holding this key for 1 sec cancels the scan LOCK KEY LOCK Push and hold for 1 sec to electronically lock all program mable keys except the following PTT Mo...

Page 13: ...Up or CH Down to select a desired list Depending on the presetting For Non display type Push to start and cancel scanning operation When the Power ON Scan Auto Scan or Rotary Selector Home function s...

Page 14: ...the optional unit connector When this key function is activated push to deactivate the function D For Simple 10 key types only Following key functions cannot be programmed to Non dis play types CH UP...

Page 15: ...hen a channel is added to the selected scan list the display quickly shows SCAN ON When a channel is deleted from the selected scan list the display quickly shows SCAN OFF 3 Hold down this key for 1 s...

Page 16: ...ck function ON and OFF All programmable keys except the following are locked PTT Moni Light Lock Emergency Surveillance and OPT 1 2 3 HIGH LOW SWITCH Selects the transmit output power temporarily Ask...

Page 17: ...nput code number may be incorrect Turn the power OFF and start over in this case When you operate Non display type the password setting is not available Channel selection Several types of channel sele...

Page 18: ...crophone 5 to 10 cm 2 to 4 in from your mouth then speak into the microphone at a normal voice level D Transmitting notes Transmit inhibit function The transceiver has several inhibit functions which...

Page 19: ...e w Push User Set Mode one or more times to select the ap propriate item Then push CH Up or CH Down to set the desired level or condition Available set mode functions are Backlight LCD contrast Beep B...

Page 20: ...Clock to indicate the current time and date on the LCD When the indication format is set to 12 hour AM or PM is indicated The LCD indication returns to the stand by mode after 30 sec has passed with n...

Page 21: ...ome information as follows Ref R Red G Green O Orange TX Lights Red while transmitting a signal TX Low BATT1 O O G G G G G G R O R O R O R O R O R O R O R O G G G Low BATT2 Low BATT1 Inh Blank CH Busy...

Page 22: ...or any other liquids Do not charge or use a wet battery pack If the battery pack gets wet be sure to wipe it dry before using R DANGER KEEP the battery pack away from fire Fire or heat may cause them...

Page 23: ...eriod of time even with little use The esti mated number of times you can charge the battery is be tween 300 and 500 Even when the battery appears to be fully charged the oper ating time of the transc...

Page 24: ...19N rapidly charges the Li Ion battery pack Charging time Approximately 4 hours for the BP 254 The following items are additionally required AD 110 charger adapter purchase separately A power adapter...

Page 25: ...ately A power adapter BC 157S or the DC power cable OPC 656 MULTI CHARGER Power adapter Purchased separately AD 110 charger adapters are installed in each slot BATTERY PACK TRANSCEIVER Turn power OFF...

Page 26: ...direction of the arrow w first then check the latch is in place e Fig 1 Be sure the gasket is set correctly and do not protrude from the battery case Fig 3 CAUTION When installing batteries make sure...

Page 27: ...speak in a normal voice level D To attach Attach the connector of the speaker microphone into the multi connector on the transceiver and tighten the screw with a coin or flat head screwdriver CAUTION...

Page 28: ...c adapter For rapid charging of up to 6 battery packs six AD 110s are required simultaneously A power adapter should be pur chased separately Charging time Approximately 4 hours for the BP 254 D CABLE...

Page 29: ...IP rating cannot be guaranteed because of possible damage to these cases or the waterproof seal Some options may not be available in some countries Please ask your dealer for details Approved Icom opt...

Page 30: ...nly VOX Gain The VOX sensitivity level can be adjusted from OFF or 1 to 6 more sensitive VOX GAIN 3 MON CLCK ZONE VOX OFF MON CLCK ZONE Push or VOX function is OFF VOX gain level 3 default VOX Delay T...

Page 31: ...also exceed FCC RF expo sure limits A proper antenna is the antenna supplied with this radio by Icom Inc or antenna specifically authorized by Icom Inc for use with this radio DO NOT transmit for more...

Page 32: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 6662D 1US i Printed in Japan 2008 2015 Icom Inc Printed on recycled paper with soy ink...