background image

ADJUSTMENT 

Adjustment          No.        Adjustment Condition & Tuning                     Value       Ref. No. CK. Point 

 

Preparation for        When there is no particular set limits, set 

Checking Modula-      the modulation analyzer for adjustment and 

tion Adjustment        checking as below. 

 

  HPF                          OFF                      

                                              LPF                        20 kHz 

                                         De-Emphasis                   OFF 

                                           Detector                 (P ± P)/2 

 

                                Connect the modulation analyzer set at the 

                                above conditions, through the attenuator to 

                                the antenna terminal. Connect an oscillo- 

scope, distortion meter and a level meter to  

the modulation analyzer’s detection output 

terminal. 

Connect a millivolt meter or a 600 ohm out- 

put impedance CR oscillator to the trans- 

ceiver’s mic terminal. 

 

Modulation                Use the adjustment software to adjust the 

Balance                     modulation analyzer’s detection output 

Adjustment                horizontal line so that it becomes a  

Straight line as below 

 

                                      Adjust. Freq.  Near Center Frequency 

                                                                                                       Detection Adj.Soft    ANT Con 

                                                                                                       Output      Balance 

 

 

Deviation                 Set the CR oscillator to a 1 kHz sine wave,  

Adjustment               40mVrms, and input from the external mic 

                               terminal. Set the transceiver to TX and use 

                               the adjustment software to adjust to the 

                               following values. 

                         

                                       Adjust. Freq.  Near Center Frequency        ± 4.05 ~  Adj.Soft   ANT Con 

                                            WIDE            ± 4.10   ± 0.05 kHz             ±4.15kHz  MOD W 

                                           NARROW          ± 2.10   ± 0.05 kHz             ± 2.05 ~  MOD N 

                                                                                                        ±2.15kHz 

 

Summary of Contents for IC-F620

Page 1: ...ring RX and C134 during TX Adj Freq 400 MHz RX Side 1 0V 1 0V C133 LV TX Side 1 1V 1 1V C134 Lock Voltage Set the transceiver to the 490 MHz Check and check that all is within specification Adj Freq 4...

Page 2: ...below Hi Power 20 0 30 0W 20 30W ANT Con L2 Power 8 0 12 5W 8 12 5W L1 Power 2 0 3 0W 2 0 3 0W Current Check at Check that the in band power consumption TX is within the specifications below Hi Power...

Page 3: ...minal Connect a millivolt meter or a 600 ohm out put impedance CR oscillator to the trans ceiver s mic terminal Modulation Use the adjustment software to adjust the Balance modulation analyzer s detec...

Page 4: ...t to the antenna terminal Set the transceiver to wide ch and CTCSS 88 5Hz Transmit while making sure no input is applied to the mic or mic terminal Adjust Freq Near Center Frequency Adj Soft ANT Con W...

Page 5: ...Hz Check that the TX S N in the bandwidth is as the values below WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB Adjusting RX When there is no particular set limits set Sensiti...

Page 6: ...rrow channels also Adjusting the This Adjustment is after the RX Sencitivity S3 LEVEL Finish Set the signal generator in the following way for wide channels Adjust Freq Near Greatest Lo band F SG Inpu...

Page 7: ...z SG Output Level 14 dBu In this condition using the adjustment Adj Soft software raise the squelch D A value until SQL the squelch closes once then lower the D A value again and adjust until the sque...

Page 8: ...e so that the AF output is 50 of the rated value Check that the RX S N in the bandwidth is as the values below WIDE More than 40 dB Over 40dB ANT Con NARROW More than 34 dB Over 34dB SP Jack Checking...

Reviews: