ADJUSTMENT
Adjustment No. Adjustment Condition & Tuning Value Ref. No. CK. Point
Checking RX Check that the signal generator level when
Sensitivity the RX frequency bandwidth becomes 12 dB
SINAD, is the value below.
RX Sensitivity Less than -10 dBu Less-10dB ANT Con
SP Jack
Use the same check method for Narrow
channels also.
Adjusting the This Adjustment is after the RX Sencitivity
S3 LEVEL Finish.
Set the signal generator in the following
way for wide channels.
Adjust Freq. Near Greatest Lo band F.
SG Input level +23 dBu
Modulation Freq. 1kHz
WIDE ± 3.5 kHz
S3 SET COMMAND with the Adjustment soft
Adj.Soft ANT Con
Ware. S-METER
S3 Level
Adjusting the
Set the signal generator to the settings
S1 LEVEL
below.
SG Output Level -7 dBu
S1 SET COMMAND with the Adjustment soft
Adj.Soft ANT Con
Ware. S-METER
S1 Level