background image

29

10

SAFETY TRAINING INFORMATION

10

9

Your Icom radio generates RF electromagnetic 
energy during transmit mode. This radio is de-
signed for and classified as “Occupational Use 
Only”, meaning it must be used only during the 
course of employment by individuals aware of the 
hazards, and the ways to minimize such hazards. 

This radio is NOT intended for use by the “General Population” 
in an uncontrolled environment.
This radio has been tested and complies with the FCC RF ex-
posure limits for “Occupational Use Only”. In addition, your Icom 
radio complies with the following Standards and Guidelines with 
regard to RF energy and electromagnetic energy levels and 
evaluation of such levels for exposure to humans:
  •  FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluat-

ing Compliance with FCC Guidelines for Human Exposure 
to Radio Frequency Electromagnetic Fields.

  •  American National Standards Institute (C95.1-1992), IEEE 

Standard for Safety Levels with Respect to Human Expo-
sure to Radio Frequency Electromagnetic Fields, 3 kHz to 
300 GHz.

  •  American National Standards Institute (C95.3-1992), IEEE 

Recommended Practice for the Measurement of Potentially 
Hazardous Electromagnetic Fields– RF and Microwave.

  •  The following accessories are authorized for use with this 

product. Use of accessories other than those specified 
may result in RF exposure levels exceeding the FCC re-
quirements for wireless RF exposure.; Belt Clip (MB-94), 
Rechargeable Li-Ion Battery Pack (BP-230N/BP-232N) and 
Speaker-microphone (HM-131SC).

To ensure that your expose to RF electro-
magnetic energy is within the FCC allowable 
limits for occupational use, always adhere 
to the following guidelines:

  •  

DO NOT

 operate the radio without a proper antenna at-

tached, as this may damaged the radio and may also cause 
you to exceed FCC RF exposure limits. A proper antenna is 
the antenna supplied with this radio by the manufacturer or 
antenna specifically authorized by the manufacturer for use 
with this radio.

  •  

DO NOT

 transmit for more than 50% of total radio use time 

(“50% duty cycle”). Transmitting more than 50% of the time 
can cause FCC RF exposure compliance requirements to 
be exceeded. The radio is transmitting when the TX indica-
tor lights red. You can cause the radio to transmit by press-
ing the “PTT” switch.

  •  

ALWAYS keep

 the antenna at least 2.5 cm (1 inch) away 

from the body when transmitting and only use the Icom belt-
clips listed on page 26 when attaching the radio to your belt, 
etc., to ensure FCC RF exposure compliance requirements 
are not exceeded. To provide the recipients of your trans-
mission the best sound quality, hold the antenna at least 5 
cm (2 inches) from your mouth, and slightly off to one side.

The information listed above provides the user with the infor-
mation needed to make him or her aware of RF exposure, and 
what to do to assure that this radio operates with the FCC RF 
exposure limits of this radio.

CAU TION

W ARNING

Summary of Contents for IC-F3061T

Page 1: ...L This device complies with Part 15 of the FCC Rules Operation is subject to the condition that this device does not cause harmful interference iF4063T S iF4061T S UHF TRANSCEIVERS iF3063T S iF3061T S...

Page 2: ...B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reason able protection against harmful interference in a residential installation This equipment generates u...

Page 3: ...el selection 11 Call procedure 11 4 LTR OPERATION 12 13 Receiving a call 12 Transmitting a call 13 5 CONVENTIONAL OPERATION 14 17 Receiving and transmitting 14 User set mode 16 Emergency transmission...

Page 4: ...peratures below 22 F 30 C or above 140 F 60 C The basic operations transmission and reception of the transceiver are guaranteed within the specified operating temperature range However the LCD display...

Page 5: ...r Connector cover with screw 1 set Some accessories are not supplied with depending on versions Accessory attachments D Flexible antenna Connect the supplied flexible antenna to the antenna connector...

Page 6: ...leased NEVER release or attach the battery pack when the transceiver is wet or soiled This may result water or dust getting into the transceiver battery pack and may result in the transceiver being da...

Page 7: ...screw CAUTION Attach the connector cover when the optional speaker microphone or head set is not used Otherwise the terminals of the multi connector may be shorted by metal object etc and this could...

Page 8: ...nsmit release to receive y DEALER PROGRAMMABLE KEYS Side2 Side3 Desired functions can be programmed independently by your dealer p 6 u 10 KEYPAD Depending on version The keypad allows you to enter dig...

Page 9: ...w o 0 q SIGNAL STRENGTH INDICATOR Indicates relative signal strength level w LOW POWER INDICATOR Appears when low output power is selected e AUDIBLE INDICATOR Appears when the channel is in the audib...

Page 10: ...nd P3 Programmable function keys The following functions can be assigned to Emer Side1 Side2 Side3 P0 P1 P2 and P3 programmable function keys Consult your Icom dealer or system operator for details co...

Page 11: ...sh CH Up or CH Down to select the de sired group SCAN ADD DEL TAG KEY SCAD Push to add or delete the selected channel to from the scan group 1 Push to indicate the scan group then push CH Up or CH Dow...

Page 12: ...elect the continuous tone channel using CH Up or CH Down to change the tone frequency code setting While in the digital mode operation push to select the RAN channel using CH Up or CH Down to change t...

Page 13: ...function ON and OFF The compander function reduces noise components from the transmitting audio to provide clear communication PHONE KEY PHN Push to connect or disconnect the telephone network con ne...

Page 14: ...cation does not clear after inputting 4 digits the input code number may be incorrect Turn the power off and start over in this case D Battery type selection The battery type must be selected accordin...

Page 15: ...Scanning stops when receiving a call Depending on the pre setting Call procedure When your system employs tone signaling excluding CTCSS and DTCS the call procedure may be necessary prior to voice tr...

Page 16: ...tion name appears and a beep is emitted Then the mute is released appears Depending on the pre setting D Phone call Receive a phone call q Push CH Up or CH Down or rotate ROTARY SELEC TOR to select th...

Page 17: ...EC TOR to select the LTR system channel or talk group w While pushing and holding PTT speak into the micro phone at a normal voice level after a beep is emitted If an error beep is emitted release PTT...

Page 18: ...eak into the micro phone at a normal voice level e Release PTT to return to receive IMPORTANT To maximize the readability of your signal 1 Pause briefly after pushing PTT 2 Hold the microphone 5 to 10...

Page 19: ...or PTT during MSK operation to transmit the selected TX code r Push TX Code CH Select again to return to the operat ing channel number indication USING TX CODE CH UP TX CODE CH DOWN KEY If the transc...

Page 20: ...Down selects the desired Status message q Push TX Status Status message and Status chan nel appears w Push CH Up or CH Down to select the desired Status message e Push PTT to transmit the selected Sta...

Page 21: ...r the optional Rolling or Non rolling type can be available q Push Scrambler to turn the scrambler function ON appears w Push Scrambler again to turn the scrambler function OFF disappears Stun functio...

Page 22: ...s in areas with temperatures above 60 C 140 F High tempera ture buildup in the battery such as could occur near fires or stoves inside a sun heated car or in direct sunlight may cause the battery to r...

Page 23: ...until the re maining capacity is about half then keep it safely in a cool dry place with the temperature between 20 C to 20 C 4 F to 68 F D Charging caution R DANGER NEVER charge the battery pack in a...

Page 24: ...nstalled into the BC 119N or BC 121N before battery charging Connect the AD 106 charger adapter and the BC 119N BC 121N as below then install the AD 106 into the holder space of the BC 119N or BC 121N...

Page 25: ...rged simultaneously The following items are additionally required Six AD 106 charger adapters An AC adapter BC 157 or the DC power cable OPC 656 Transceiver Battery pack AD 106 charger adapters are in...

Page 26: ...RGING IMPORTANT Battery charging caution Ensure the guide lobs on the battery pack are correctly aligned with the guide rails inside the charger adapter This illustration is described with the BC 160...

Page 27: ...the arrow e then close r And hook the battery cover release hook until it makes a click sound t Fig 3 CAUTION When installing batteries make sure they are all the same brand type and capacity Also do...

Page 28: ...ection of the arrow until the base clip is locked and makes a click sound e Clip the belt clip to a part of your belt And insert the transceiver into the belt clip until the base clip inserted fully i...

Page 29: ...it is attached p 2 e Pinch the clip q and slide the base clip in the direction of the arrow w CAUTION HOLD THE TRANSCEIVER TIGHTLY WHEN HANGING OR DETACHING THE TRANSCEIVER FROM THE BELT CLIP Otherwi...

Page 30: ...The same as supplied with the transceiver MB 96N 96F leather belt hanger D OPTIONAL UNITS UT 96R 2 5 tone unit UT 109R UT 110R scrambler units Non rolling type UT 109R Rolling type UT 110R voice scra...

Page 31: ...SC25V Frequency range 136 150 MHz FA SC55V Frequency range 150 174 MHz FA SC25U Frequency range 400 430 MHz FA SC57U Frequency range 430 470 MHz FA SC72U Frequency range 470 520 MHz Some options may n...

Page 32: ...exit user set mode VOX Gain The VOX sensitivity level can be adjusted from OFF or 1 to 6 more sensitive VOX Delay The VOX delay time can be set from 0 5 to 3 0 sec 0 5 sec step for a convenient inter...

Page 33: ...eding the FCC re quirements for wireless RF exposure Belt Clip MB 94 Rechargeable Li Ion Battery Pack BP 230N BP 232N and Speaker microphone HM 131SC To ensure that your expose to RF electro magnetic...

Page 34: ...the radio in areas where signs are posted to do so DO NOT operate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals aircraft and blasting sites Occupational C...

Page 35: ...31 MEMO 10...

Page 36: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 6488D 1EX w Printed in Japan 2006 2008 Icom Inc Printed on recycled paper with soy ink...

Reviews: