5 - 5
5-3 SOFTWARE ADJUSTMENT
Select an operation using [
↑
] / [
↓
] keys, then set specified value using [
←
] / [
→
] keys on the connected computer keyboard.
1
1
2
3
1
2
1
2
1
• Operating freq. : 174.000 MHz
• Output power : Low1
• Connect the RF power meter or 50
Ω
dummy load to the antenna connector.
• Transmitting
• Operating freq. : 155.000 MHz
• Output power : High
• Transmitting
• Output power : Low2
• Transmitting
• Output power : Low1
• Transmitting
• Operating freq. : 155.000 MHz
• Output power : Low1
• IF bandwidth
: Wide
• Connect an audio generator to the [MIC]
jack through the JIG cable and set as:
1.0 kHz/40 mVrms
• Set an FM deviation meter as:
HPF
: OFF
LPF
: 20 kHz
De-emphasis : OFF
Detector
: (P–P)/2
• Transmitting
• IF bandwidth
: Narrow
• Transmitting
• Set to the DTCS set channel, and push
[Connect] on the adjustment software.
• Operating freq. : 174.000 MHz
• Output power : Low1
• Transmitting
• IF bandwidth
: Narrow
• Transmitting
• Operating freq. : 155.000 MHz
• Output power : Low1
• IF bandwidth
: Wide
• CTCSS
: 88.5 Hz
• DTCS code
: 007
• Set the FM deviation meter as:
HPF
: OFF
LPF
: 20 kHz
De-emphasis : OFF
Detector
: (P–P)/2
• No audio applied to the [MIC] connector.
• Transmitting
REFERENCE
FREQUENCY
[TXF]
OUTPUT
POWER
[Power (Hi)]
[Power (L2)]
[Power (L1)]
FM
DEVIATION
[MOD W]
[MOD Ratio]
MODULATION
BALLANCE
[BAL W]
[BAL Ratio]
CTCSS/DTCS
DEVIATON
[CTCS/DTCS]
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Loosely couple a frequnecy
counter to the antenna connec-
tor.
Connect an RF power meter to
the antenna connector.
Connect an FM deviation meter
to the antenna connector
through the attenuator.
Connect an FM deviation meter
with an oscilloscope to the
antenna connector through an
attenuator.
Connect an FM deviation meter
to the antenna connector
through the attenuator.
174.0000 MHz
25.0 W [25 W]
50.0 W [50 W]
10.0 W [25W]
25.0 W [50 W]
2.5 W [25W]
5.0 W [50 W]
±4.1 kHz
[N/W]
±3.3 kHz
[N/M]
±2.1 kHz
±0.68 kHz [N/W]
±0.56 kHz [N/M]
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT
LOCATION
Set to square wave
form
Summary of Contents for IC F110S
Page 1: ...SERVICE MANUAL VHF TRANSCEIVER iF110S iF111S iF121S ...
Page 31: ...SP 14 8 1 1 7 14 8 7 12 24 1 13 9 4 BOTTOM VIEW MAIN UNIT ...
Page 36: ......
Page 37: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 13906HZ C1VS e 2003 Icom Inc ...
Page 38: ...SERVICE MANUAL UHF TRANSCEIVER iF210S iF211S iF221S ...
Page 68: ...SP 14 8 1 1 7 14 8 7 12 24 1 13 9 4 BOTTOM VIEW MAIN UNIT ...
Page 73: ......
Page 74: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 13906HZ C1US w C 2002 2003 Icom Inc ...