background image

Cmd. Sub cmd.

Data

Description

07

00 or 01

Read the Overflow status

( 00=OVF indicator is OFF, 01=OVF indicator is ON)

11

0000 ~ 0255 Read the PO meter level

(0000=0% to 0143=50% to 212=100%)

12

0000 ~ 0255 Read SWR meter level

(   0000=SWR1.0,  0048=SWR1.5,

 0080=SWR2.0, 0120=SWR3.0)

13

0000 ~ 0255 Read ALC meter level

(0000=Min. to 0120=Max.)

14

0000 ~ 0255 Read COMP meter level

(0000=0 dB, 0130=15 dB, 0241=30 dB)

15

0000 ~ 0255 Read Vd meter level

(0000=0 V, 0151=10 V, 0211=16 V)

16

0000 ~ 0255 Read Id meter level

( 0000=0A, 0077=10A, 0165=20A, 0241=30A)

16* 02

00

Preamp OFF

01

Preamp 1 ON

02

Preamp 2 ON

12

01 ~ 03

Set the AGC time constant

(01=FAST, 02=MID, 03=SLOW)

22

00 or 01

Set the Noise blanker 

(00=OFF, 01=ON)

32

00

Audio peak filter OFF

01

Audio peak filter WIDE ON

(320 Hz is selected when SHARP APF is set)

02

Audio peak filter MID ON

(160 Hz is selected when SHARP APF is set)

03

Audio peak filter NAR ON

(80 Hz is selected when SHARP APF is set)

40

00 or 01

Set the Noise reduction

(00=OFF, 01=ON)

41

00 or 01

Set the Auto Notch function

(00=OFF, 01=ON)

42

00 or 01

Set the Repeater tone

(00=OFF, 01=ON)

43

00 or 01

Set the Tone squelch

(00=OFF, 01=ON)

44

00 or 01

Set the Speech compressor 

(00=OFF, 01=ON)

45

00 or 01

Set the Monitor [MONI] function

(00=OFF, 01=ON)

46

00 or 01

Set the VOX function

(00=OFF, 01=ON)

47

00

BK-IN function OFF

01

Semi BK-IN function ON

02

Full BK-IN function ON

48

00 or 01

Set the Manual Notch function

(00=OFF, 01=ON)

4E

00 or 01

Set the DIGI-SEL function

(00=OFF, 01=ON)

4F

00 or 01

Set the Twin peak filter

(00=OFF, 01=ON)

( Can be turned ON only when Mark and Shift 

are set to 2125 Hz and 170 Hz, respectively)

50

00 or 01

Set the Dial lock function

(00=OFF, 01=ON)

53*

2

00 or 01

Set the ANT-RX I/O

(00=OFF, 01=ON)

56

00 or 01

Set the DSP IF filter type

(00=SHARP, 01=SOFT)

57

00 ~ 02

Set the Manual Notch width

(00=WIDE, 01=MID, 02=NAR)

58

00 ~ 02

Set the SSB transmit bandwidth

(00=WIDE, 01=MID, 02=NAR)

( One of following values is applied, depending 

on the “COMP” status (ON or OFF):

 WIDE (Command: 1A 05 0015),  

 MID (Command: 1A 05 0016) or 

 NAR (Command: 1A 05 0017))

5E

00 or 01

MAIN/SUB Tracking function

(00=OFF, 01=ON)

65

00 or 01

Set the IP Plus function

(00=OFF, 01=ON)

 

D

Command table (Continued)

Cmd. Sub cmd.

Data

Description

17*

3

see p. 10

Send CW messages

18

00

Turn OFF the transceiver

01*

4

Turn ON the transceiver

19

00

Read the transceiver ID

1A* 00

see p. 11

Send/read memory contents

01

see p. 10

Send/read band stacking register contents

02*

6

see p. 13

Send/read memory keyer contents

03

see p. 12

Send/read the selected IF filter width

04

see p. 12

Send/read the selected AGC time constant

05 0001

see p. 12

Tone Control > RX > 

Send/read SSB RX HPF/LPF settings

0002

00 ~ 10

Tone Control > RX > 

Send/read SSB RX Tone (Bass) level

(00=–5 to 10=+5)

0003

00 ~ 10

Tone Control > RX > 

Send/read SSB RX Tone (Treble) level 

(00=–5 to 10=+5)

0004

see p. 12

Tone Control > RX > 

Send/read AM RX HPF/LPF settings

0005

00 ~ 10

Tone Control > RX > 

Send/read AM RX Tone (Bass) level

(00=–5 to 10=+5)

0006

00 ~ 10

Tone Control > RX > 

Send/read AM RX Tone (Treble) level

(00=–5 to 10=+5)

0007

see p. 12

Tone Control > RX > 

Send/read FM RX HPF/LPF settings

0008

00 ~ 10

Tone Control > RX > 

Send/read FM RX Tone (Bass) level

(00=–5 to 10=+5)

0009

00 ~ 10

Tone Control > RX > 

Send/read FM RX Tone (Treble) level

(00=–5 to 10=+5)

0010

see p. 12

Tone Control > RX > 

Send/read CW RX HPF/LPF settings

0011

see p. 12

Tone Control > RX > 

Send/read RTTY RX HPF/LPF settings

0012

see p. 12

Tone Control > RX > 

Send/read PSK RX HPF/LPF settings

0013

00 ~ 10

Tone Control > TX > 

Send/read SSB TX Tone (Bass) level

(00=–5 to 10=+5)

0014

00 ~ 10

Tone Control > TX > 

Send/read SSB TX Tone (Treble) level 

(00=–5 to 10=+5)

0015

see p. 12

Tone Control > TX > 

Send/read SSB TX bandwidth for wide

0016

see p. 12

Tone Control > TX > 

Send/read SSB TX bandwidth for mid

0017

see p. 12

Tone Control > TX > 

Send/read SSB TX bandwidth for narrow

0018

00 ~ 10

Tone Control > TX > 

Send/read AM TX Tone (Bass) level

(00=–5 to 10=+5)

0019

00 ~ 10

Tone Control > TX > 

Send/read AM TX Tone (Treble) level 

(00=–5 to 10=+5)

0020

00 ~ 10

Tone Control > TX > 

Send/read FM TX Tone (Bass) level

(00=–5 to 10=+5)

0021

00 ~ 10

Tone Control > TX > 

Send/read FM TX Tone (Treble) level 

(00=–5 to 10=+5)

0022 0000 ~ 0255 Function > Beep Level

(0000=min. to 0255=max.)

0023

00 or 01

Function > Beep Level Limit

(00=OFF, 01=ON)

0024

00 or 01

Function > Beep (Confirmation)

(00=OFF, 01=ON)

0025

00 or 01

Function > Band Edge Beep

(00=OFF, 01=ON)

( ON = Beep sounds with a default amateur 

band)

02

Function > Band Edge Beep

(02=ON (User))

03

Function > Band Edge Beep

(03=ON (User) & TX Limit)

15

Remote control

4

Summary of Contents for IC-7610

Page 1: ...CI V REFERENCE GUIDE i7610 HF 50MHz TRANSCEIVER...

Page 2: ...Table of contents 1 1 Remote control 2 Remote control CI V information 2 D D CI V connection 2 D D Preparing 2 D D About the data format 2 D D Command table 3 D D Command formats 10...

Page 3: ...he CI V system can be written using the following data formats Data formats differ according to command numbers A data area or sub command is added for some commands Controller to IC 7610 IC 7610 to c...

Page 4: ...d read 36 dB attenuator setting 39 Send read 39 dB attenuator setting 42 Send read 42 dB attenuator setting 45 Send read 45 dB attenuator setting 12 00 1 00 or 01 Select read ANT1 selection 00 RX ANT...

Page 5: ...unction 00 OFF 01 ON D D Command table Continued Cmd Sub cmd Data Description 17 3 see p 10 Send CW messages 18 00 Turn OFF the transceiver 01 4 Turn ON the transceiver 19 00 Read the transceiver ID 1...

Page 6: ...Function NOTCH Switch AM 00 Auto 01 Manual 02 Auto Manual 0060 00 or 01 Function FILTER Screen MAIN SUB Select 00 Fix 01 Auto by FILTER PBT Operation 0061 00 or 01 Function SSB CW Synchronous Tuning...

Page 7: ...to REMOTE 0116 00 or 01 Connectors CI V CI V USB Echo Back 00 OFF 01 ON 0117 00 07 Connectors External Meter External Meter Output MAIN 00 Auto 01 S main 02 Po 03 SWR 04 ALC 05 COMP 06 Vd 07 Id 0118 0...

Page 8: ...rge 0178 00 09 SCOPE Waterfall Peak Color Level 00 Grid 1 to 09 Grid 10 0179 00 or 01 SCOPE Waterfall Marker Auto hide 00 OFF 01 ON 0180 00 or 01 SCOPE Dual Scope Type 00 Over Under 01 Side by Side 01...

Page 9: ...01 RX Only 0267 00 or 01 Recorder Set TX REC Audio 00 Direct 01 Monitor 0268 00 or 01 Recorder Set RX REC Condition 00 Always 01 Squelch Auto 0269 00 or 01 Recorder Set File Split 00 OFF 01 ON D D Co...

Page 10: ...ption 1E 00 Read number of available TX frequency band 01 see p 10 Read TX band edge frequencies 02 Read number of user set TX frequency band 03 see p 10 Send read user set TX band edge frequencies 21...

Page 11: ...nd edge frequency settings Command 02 1E 01 1E 03 When obtaining the edge number by command 02 the edge number q is not returned q X X X w e r t y u i o 0 1 2 X X X X X X X 0 0 2 D X X X X X X X X 0 0...

Page 12: ...r the memory channel contents on 1A 00 q w Memory channel 0001 0099 e FF r None 0 X e 0 OFF Fixed 1 1 2 2 3 3 X X 1 0 OFF 1 TONE 2 TSQL 0 OFF 1 DATA 1 2 DATA 2 3 DATA 3 Codes for character entries Com...

Page 13: ...rating mode Command 1A 05 0001 05 0004 05 0007 05 0010 05 0011 05 0012 X X X X LPF Upper edge HPF Lower edge The value of the HPF should be smaller than the LPF HPF 00 Through 01 20 100 2000 Hz LPF 05...

Page 14: ...gs Command 21 00 10 Hz 0 9 100 Hz 0 9 1 Hz 0 9 1 kHz 0 9 X X X X X X 00 plus 01 minus Repeater tone tone squelch frequency settings Command 1B 00 1B 01 100Hz digit 0 2 10 Hz digit 0 9 1 Hz digit 0 9 0...

Page 15: ...gether However when the data is sent through the USB port the data is divided by 15 and sent in sequential order Division number Data length LAN 01 704 USB 15 1st data 15 2nd or later data 53 15th dat...

Page 16: ...t y u i o 0 1 2 X X X X X X X 0 0 X X X X X X X X 0 0 10 Hz digit 0 9 1 Hz digit 0 9 1 kHz digit 0 9 100 Hz digit 0 9 100 kHz digit 0 9 10 kHz digit 0 9 10 MHz digit 0 6 1 MHz digit 0 9 1 GHz digit 0...

Page 17: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A7380 7EX 2017 Icom Inc...

Reviews: