![Icom IC-7610 Reference Manual Download Page 16](http://html2.mh-extra.com/html/icom/ic-7610/ic-7610_reference-manual_4140935016.webp)
D
Command formats (Continued)
•
Scope Reference level settings
Command: 27 19
X X X X X 0 X X
00= + (plus)
01= – (minus)
00= MAIN
01= SUB
10 dB digit:
0, 1, 2
1 dB digit:
0–9
0.1 dB digit:
0, 5
0.01 dB digit:
0
(Fix
ed)
L
Adjustable range: –30.0 dB ~ +10.0 dB in 0.5 dB steps
•
Scope Sweep speed settings
Command: 27 1A
X X X X
00=FAST
01=MID
02=SLOW
00=MAIN
01=SUB
•
Scope VBW (Video Band Width) settings
Command: 27 1D
X X X X
00=Narrow
01=Wide
00=MAIN
01=SUB
•
Scope RBW (Resolution Band Width) settings
Command: 27 1F
X X X X
00=WIDE
01=MID
01=NAR
00=MAIN
01=SUB
•
Scope Fixed edge frequency settings
Command: 27 1E
q
0 X
X X
X
w
e
r
t
y
u
i
o
!0
!1
!2
X X X X X X X 0 0 X X X X X X X X 0 0
10 Hz
digit:
0–
9
1 Hz
digit:
0–
9
1 kHz
digit:
0–
9
100 Hz
digit:
0–
9
100 kHz
digit:
0–
9
10 kHz
digit:
0–
9
10 MHz
digit:
0–6
1 MHz
digit:
0–
9
1 GHz
digit:
0 (fixed)
100 MHz
digit:
0 (fixed)
10 Hz
digit:
0–
9
1 Hz
digit:
0–
9
1 kHz
digit:
0–
9
100 Hz
digit:
0–
9
100 kHz
digit:
0–
9
10 kHz
digit:
0–
9
10 MHz
digit:
0–6
1 MHz
digit:
0–
9
1 GHz
digit:
0 (fixed)
100 MHz
digit:
0 (fixed)
Frequency range
Lower edge
Higher edge
Edge number: 01–03
L
Entry of 100 Hz or smaller digits are ignored.
q
Selectable Frequency ranges
Data Frequency range (Hz)
01
0.03 ~ 1.60
02
1.60 ~ 2.00
03
2.00 ~ 6.00
04
6.00 ~ 8.00
05
8.00 ~ 11.00
06
11.00 ~ 15.00
07
15.00 ~ 20.00
08
20.00 ~ 22.00
09
22.00 ~ 26.00
10
26.00 ~ 30.00
11
30.00 ~ 45.00
12
45.00 ~ 60.00
w
Selectable Edge number: 01=1, 02=2, 03=3
Remote control
15