![Icom IC-7610 Reference Manual Download Page 10](http://html2.mh-extra.com/html/icom/ic-7610/ic-7610_reference-manual_4140935010.webp)
D
Command table (Continued)
*4 When sending the power ON command (18 01), you need
to repeatedly send “FE” before the standard format. The
following is the approximate number of needed repetitions.
• 115200 bps: 150 “FE”s
• 57600 bps: 75 “FE”s
• 38400 bps: 50 “FE”s
• 19200 bps: 25 “FE”s
• 9600 bps: 13 “FE”s
• 4800 bps: 7 “FE”s
×7
Example: When using 4800 bps
F
8
9
E
F
E
F E
E
1
0
8
1
0
D
F
Preamble
7610’s
address
Controller’s
address
Command
Sub
command
Post
amble
*5 Read only data
*6 To insert a counter, first clear the other channel’s counter.
*7
When you use the [USB 1] port, you need to select “Unlink
from [REMOTE]” in the “CI-V USB port” item, and you
need to select “115200” in the “CI-V Baud Rate” item.
MENU
» SET > Connectors >
CI-V
You can use the [LAN] port, regardless of those settings.
You cannot use the [REMOTE] terminal, regardless of
those settings.
*1 If the Antenna Type is set to
“
RX-I/O,” command “01 (RX
ANT ON)” is invalid and “00 (RX ANT OFF)” is always
returned.
*2 If the Antenna Type is set to “RX-ANT,” command “01
(ON)” is invalid and “00 (OFF)” is always returned.
*3 In the CW mode, if the [TRANSMIT] or an external TX
switch is ON, or the Break-in function is ON, a message
will be transmitted as CW code when you send it from
your PC.
*(Asterisk) Send/read data
Cmd. Sub cmd.
Data
Description
1E
00
Read number of available TX frequency band
01
see p. 10
Read TX band edge frequencies
02
Read number of user-set TX frequency band
03*
see p. 10
Send/read user-set TX band edge
frequencies
21* 00
see p. 13
RIT frequency
01
00 or 01
RIT setting
(00=OFF, 01=ON)
02
00 or 01
∂
TX setting
(00=OFF, 01=ON)
25*
see p. 13
Main or sub band frequency
26*
see p. 13
Send/read the operating mode and filter
setting (for both Main and Sub bands)
27* 00
see p. 14
Read the Scope waveform data
( Only when “Scope ON/OFF status”
(Command: 27 10) and “Scope data output”
(Command: 27 20) are set to “ON,” outputs
the waveform data to the controller.)
10
00 or 01
Scope ON/OFF status
(00=OFF, 01=ON)
11*
7
00 or 01
Scope wave data output
(00=OFF, 01=ON)
12
00 or 01
Main or Sub scope setting
(00=Main, 01=Sub)
13
00 or 01
Single/Dual scope setting
(00=Single, 01=Dual)
14
see p. 14
Scope Center mode or Fixed mode setting
15
see p. 14
Span setting in the Center mode Scope
16
see p. 14
Edge number setting in the Fixed mode
Scope
17
see p. 14
Scope hold function ON or OFF
19
see p. 15
Scope Reference level setting
1A
see p. 15
Sweep speed setting
1B
00 or 01
SCOPE > Scope during Tx (CENTER TYPE)
(00=OFF, 01=ON)
1C
00 ~ 02
SCOPE > CENTER Type Display
(00=Filter center, 01=Carrier point center,
02=Carrier point center (Abs. Freq.))
1D
see p. 15
Scope VBW setting
1E
see p. 15
Scope Fixed edge frequencies
1F
see p. 15
Scope RBW setting
28
00
00 ~ 08
Voice TX Memory
(00=Stop, 01=T1 to 08=T8)
Remote control
9