12 .
Lockout
(0-8°, NITE, COOL-HEAT)
Select the number of degrees set temperature can be changed during
keypad lockout or select to lockout during
NITE
period only .
COOL-HEAT
lockout allows adjustment of the set temperatures to the maximum heat
set temperature selected in Step 13 and minimum cool set temperature
selected in Step 14 .
Note:
The mode cannot be changed when the thermostat is locked .
Press the
up
or
down
button to select .
Press the
right
button to advance to the next screen .
13 .
Maximum Heat Setpoint
(45°F to 90°F) (7°C to 32°C)
Adjust to control the maximum heat set temperature allowed .
Press the
up
or
down
button to select .
Press the
right
button to advance to the next screen .
14 .
Minimum Cool Setpoint
(45°F to 90°F) (7°C to 32°C)
Adjust to control the minimum cool set temperature allowed .
Press the
up
or
down
button to select .
Press the
right
button to advance to the next screen .
11. Auxiliary Delay ON
(0-30 minutes)
Set the delay time in minutes for auxiliary heat to be locked out after a call
for second stage . This extra savings feature is used to temporarily lock out
auxiliary heat devices, allowing just heat pump to try to satisfy heat call .
Press the up or down button to select .
Press t
he
right
button to advance to the next screen .