General information
7
APPLIANCE DESCRIPTION
The
BNX
steam generators are automatically operated single-block appliances.
The horizontal combustion chamber is with flame inversion and the tube bundle is complete with helical turbulators.
The single front door is thermally insulated with refractory materials and is mounted on adjustable hinges, easily opened without
having to remove the burner; it is equipped with visor for flame control.
The smoke box is fixed with bolts to the back of the generator. It is equipped with smoke duct fitting, cleaning door and can be
dismantled.
The body is thermally insulated with high density rock wool mat, protected with stainless steel panels.
They use a single control panel in which the entire electrical wiring converges.
The appliance rests on a carbon steel profile base that ensures its stability.
The
BNX
steam generators have obtained suitability for liquid and gaseous fuels for the production of low pressure (0,7-0,9 bar)
100 to 3000 kg/h steam.
STRUCTURE
1
Electrical panel
2
Adjustment pressure switch(es)
3
Block pressure switch
4
Pressure gauge
5
1st safety level probe (minimum)
6
Level adjustment probes (start/stop)
7
2nd safety level probe (minimum)
8
Level indicator
9
Level indicator discharge
10
Front door
11
Level test valves
12
Flame control warning light
13
Burner application plate
14
Steam inlet valve
15
Steam dome
16
Inspection hatch
17
Safety valve
18
Supply filter
19
Rear smoke chamber
20
Chimney fitting
21
Cleaning door
22
Drain valve
23
Supply electric pump (2 electric
pumps only for EXP versions)
24
Check valves
25
Supply valve
26
Auxiliary supply valve
27
Pressure gauge valve
N1
Steam inlet
N2
Supply
N3
Safety valve drain
N4
Boiler drain
N5
Safety valve connection
N6
Auxiliary supply
Cooke Industries - Phone: +64 9 579 2185 Email: [email protected] Web: www.cookeindustries.co.nz