32
[ 4 - 2 3 ] C o m p .
R u n b y f o r c e
R u n b y f o r c e
1 . W o r k i n g ? : O f f
2 . S e n s i n g T i m e : 4 m i n
3 . S e n s i n g T e m p : - 8 . 0 C
4 . R u n T i m e : 1 5 s e c
4-22:
Compressor delay time setting
This sets the compressor's operation delay time after
making soft ice cream. If this category is given much
time, soft ice cream can be frozen too much and
problems can occur to the product.
4-23/4-23-1: Selection of the compressor forced operation
This is the function for forcibly operating the compressor
during rest time when the compressor is not operating.
The following categories appear when this category
is turned on.
4-20:
Calibration of voltage measurement value
The function aligns voltage measured during
installation of the product with voltage indicated on
[ POWER ] on the information checking window. The
two voltages be shall kept identical to each other with
this function.
4-21:
Dasher motor delay time setting
Sets the motors operation delay time after making
soft ice cream.
4-23-2:
Temperature detection time setting after stop
This chooses the time to determine the temperature during the rest time.
In case ‘
4min
’
is chosen, it means, detecting temperature 4minutes after rest.
It sets the temperature for operating the compressor.
The compressor is operated when the temperature reaches the temperature that has been
set for this category.
4-23-3: Operation temperature selection
This detects the temperature at the time set in
Category ‘
4-23-3
’ and sets the temperature at
which the compressor can be operated.
The compressor is operated when the temperature
reaches the temperature that was set for this category.
4-23-4: Operation time control
In case the temperature reaches the temperature of ‘
4-23-3
’ at the time of ‘
4-23-2
’ ,
it sets the time for compressor operation.
Explanation of the function buttons (set by an Administrator)
[ 4 - 2 0 ] V o l t a g e
C a l i b r a t i o n
: 0 V
[ 4 - 2 2 ] C o m p . D e l a y
[ 4 - 2 3 ] C o m p .
: 0 s e c
[ 4 - 2 1 ] M o t o r
D e l a y T i m e
1 . I n i t i a l : 3 0 0 s e c
2 . N o t I n i t i a l : 1 0 s e c
[ 4 - 1 8 ] R e f r e s h
1 . W o r k i n g ? : O n
2 . B u t t o n I n p u t : 2 0 s e c
3 . B u t t o n B a n : 6 0 s e c
4-18/4-81-1: Select the use of refresh.
4-18-2: Refresh time setting
Set the refresh’s Operating time.
4-18-3: Set the refresh’s work limit time
Set the limit time in order to prevent continuous operation after refresh movement.
Refresh can be used again when the time set for this category has passed.