31
[ 4 - 1 6 ] C u r r e n t C o r r e c t
[ 4 - 1 7 ] A i r P u m p ( L e f t )
4 . B u t t o n I n p u t : 1 5 s e c
[ 4 - 1 7 ] A i r P u m p ( L e f t )
: 0 . 0 A
1 . W o r k i n g ? : O f f
2 . I n i t i a l T i m e : 3 0 m i n
3 . D r a w D e l a y : 1 5 s e c
4-17-2: Operation time setting during the initial operation
Set the operation time of the air pump when
beginning initial operation.
4-17-3: Operation time setting after sales
Set the operation delay time of the air pump sales. After the motor operation is stopped,
the air pump is additionally operated according to the time set for this category.
4-16: Current value compensation setting
This is the function for performing overall compensation
when the measured current is different from the actual
measurement value.
4-17/4-17-1: Air pump selection
If the model has an air pump, this category can be
turned on to control the operation of the air pump.
4-17-4: Operation time set after button input
(
Applying the relevant model)
Set the time that the air pump operates every time
the button is pushed.
Explanation of the function buttons (set by an Administrator)
[ 4 - 1 3 ] P o w e r ( L e f t )
1 . P o w e r C h e c k : O n
2 . V o l t a g e : 2 2 0 V
3 . H e r t z : 6 0 H z
4-13/4-13-1: Supply power standard value setting
Set the voltage and frequency standard of supply power.
When this function is on, the following category
appears.
4-13-2: Voltage standard value setting
Measure the voltage at the place of installation and enter the standard value.
This product guarantees
±10% of the supply power. When it is outside of the range a warning
sound is given. If used continually, the product can have problems.
As for voltage of single phase, it is required to measure voltage of L and N.
When voltage is 3W, 3 phases, voltage shall be adjusted based on the phase voltage.
4-13-3: Frequency standard value setting
Set the frequency standard of the supply power.
When the standard value of this category is wrongly selected, the present supply voltage of ‘ 1-3’
can be displayed differently.
[ 4 - 1 2 ] C u r r e n t S e t
4-12:
No load detection function setting
The no load detection function can be turned ON/OFF.
‘ No load’ means the raw material inside the
cylinder exists in a liquid condition.
The motor current is then called ‘ no load current’
If this function is set to on, power is allowed to the product
and the noload current is remembered when
the temperature of the cylinder is higher than 5
℃
.
: O n