1
Descriptions
ON
Drain after harvest
OFF
Drain after ice making
2
Descriptions
ON
Use drain function
OFF
Do not use drain function
(All the drain time : oFF)
- Initial dump : basic process
1) It only works at the beginning of the first “ice making".
2) Check the water level sensor and operate the dump valve and water pump in case of high water level.
3) When the low level is detected, the dump valve and the water pump are stopped.
4) The maximum drain time is 30 seconds.
5) After the initial drainage is completed, the water supply enters operation.
Model
Initial drain
time
Drain after
harvest
Drain after ice
making
Water supply
delay time
Pump stop
time during ice
making
Harvest Assist
Temperature
30” Series
20s
10s
N/A (20s)
15s
N/A (15s)
N/A (32F)
22” Series
20s
10s
N/A (10s)
5s
N/A (0s)
N/A (32F)
1100 Series
20s
10s
N/A (10s)
30s
N/A (15s)
N/A (32F)
3
Descriptions
ON
Air cooled
OFF
Water cooled
4
5
Descriptions
ON
ON
IM-0350/0460/0550-
22 Series(22”)
ON
OFF
IM-1100 Series
OFF
ON
TBD
OFF
OFF
IM-0350/0460
/0550/0680
Series(30”)
IM-0350/0460
0550/0680
Air cooled model
IM-0460/0680
Water cooled
Model
IM-0350/0460
0550-
22(22”)
Water Cooled
Model
IM-1100
Water cooled
Model
IM-0350/0460
0550-
22(22”)
Air Cooled model
IM-1100
Air cooled
Model
2.2 IM series PCB _ Dip switch setting
Should a replacement board be needed, insure setting is correct for model of ice maker
Summary of Contents for IM Series
Page 6: ...DOOR ON HINGE ACCESS TO DIAGNOSTICS PANEL Door can rest on top of machine if needed...
Page 8: ...Non Corrosive Platform...
Page 11: ...NEW WATER DISTRIBUTION TUBE REMOVABLE NO TOOLS...
Page 12: ...DISTRIBUTOR TUBE REMOVED FOR CLEANING WATER SUPPLY FROM PUMP WHEN DISTRIBUTOR TUBE IS REMOVED...
Page 14: ...CLOSE UP OF CURTAIN HOLDERS DISTRIBUTOR TUBE THUMB KNOBS...
Page 17: ...WATER PUMP MOTOR OUT OF WET ZONE EASY ACCESS TO PUMP...
Page 19: ...ACCESS PORTS IM Series Indication label of high pressure Low pressure nipple of compressor...
Page 20: ...Replacing a pressure switch Use a Pinch Off tool when possible...
Page 21: ...MAGNETIC FRAME CLEANABLE CONDENSER AIR FILTER...
Page 22: ......
Page 28: ...WATER REFRIGERANT FLOW...
Page 29: ...HARVEST CYCLE...
Page 31: ...PLASTIC COVER PIECE WITH KIT BAFFLE TO BE FURNISHED BY DISPENSER MFG...
Page 37: ......
Page 38: ...Error Code Indicator Lights Diagnostics FNB BOARD ERROR CODE INFO...
Page 39: ...FNB BOARD ERROR CODE INFO...
Page 41: ...IM SERIES WIRING DIAGRAM...
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ...Thank You...