1.
With Water Curtain closed, Dump Valve and Water Valve are energized for 15 seconds.(set time) With brackish water pumped
from the Sump Trough, Water Pump and Dump Valve are de-energized.
2.
After 15 seconds Dump Valve is de-energized. But Water Valve is energized until water level sensor reaches high level plus 15
seconds. Fan motor energized after 5 seconds with Water Curtain closed.
3.
When water contacts Ice Thickness Sensor for 7 continuous seconds, the machine enters defrost.
4.
Hot Gas Valve are energized for approximately 50 seconds. At this time, the Pump Motor and the Water supply valve are de-
energized.
5.
Compressor and Hot Gas Valve continue to defrost evaporator until ice falls from evaporator plate.
6.
Ice falling from evaporator cause Water Curtain open then closes when ice clears the Evaporator signaling defrost termination.
7.
With the Curtain closed, the machine begins another cycle.
•
After shut down due to full bin level and lighting of “Full Lamp”, removal of ice from bin will cause the Curtain to close wh
ich c
loses the Curtain Switch and energize the machine with the same steps as “INITIAL START
-
UP”.
•
* Normal continuous operation starts a new cycle with steps 1 through #7.
NORMAL CONTINUOUS SEQUENCE OF OPERATION DURING ICE MAKING MODE IM SERIES
Summary of Contents for IM Series
Page 6: ...DOOR ON HINGE ACCESS TO DIAGNOSTICS PANEL Door can rest on top of machine if needed...
Page 8: ...Non Corrosive Platform...
Page 11: ...NEW WATER DISTRIBUTION TUBE REMOVABLE NO TOOLS...
Page 12: ...DISTRIBUTOR TUBE REMOVED FOR CLEANING WATER SUPPLY FROM PUMP WHEN DISTRIBUTOR TUBE IS REMOVED...
Page 14: ...CLOSE UP OF CURTAIN HOLDERS DISTRIBUTOR TUBE THUMB KNOBS...
Page 17: ...WATER PUMP MOTOR OUT OF WET ZONE EASY ACCESS TO PUMP...
Page 19: ...ACCESS PORTS IM Series Indication label of high pressure Low pressure nipple of compressor...
Page 20: ...Replacing a pressure switch Use a Pinch Off tool when possible...
Page 21: ...MAGNETIC FRAME CLEANABLE CONDENSER AIR FILTER...
Page 22: ......
Page 28: ...WATER REFRIGERANT FLOW...
Page 29: ...HARVEST CYCLE...
Page 31: ...PLASTIC COVER PIECE WITH KIT BAFFLE TO BE FURNISHED BY DISPENSER MFG...
Page 37: ......
Page 38: ...Error Code Indicator Lights Diagnostics FNB BOARD ERROR CODE INFO...
Page 39: ...FNB BOARD ERROR CODE INFO...
Page 41: ...IM SERIES WIRING DIAGRAM...
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ...Thank You...