6. Cleaning (at least once a month)
1. Turn off the top right power switch. (IM/WM-0460-AC/AH/WC/WH,
IM/WM-0460-AC/AH(115V), IM/WM-0460-AC/AH/WC/WH-22,
IM/WM-0680-AC/AH/WC/WH)
1. Turn off the power switch inside the front cover.
(IM/WM-1100-AC/AH/WC/WH, IM-1100-RC/RH)
2. Detach the drain plug to remove any residue in the vessel.
3. Detach the water curtain and clean the square panel with soft cloth when cleaning the
evaporator.
4. Detach the water distributor and clean it thoroughly.
5. Dilute mild detergent (for home use) to clean the product (1 spoonful per liter of water). After
cleaning the product with detergent, be sure to rinse the product for more than 20 minutes; there
should be no bubbles left from detergent.
※
Do not use detergent for laundry.
WATER DISTRIBUTOR
DRAIN SWITCH (WM-0460 (22") / WM-0680 (30"))
ICE THICKNESS SENSOR
WATER DISTRIBUTOR
ICE THICKNESS SENSOR
ICE THICKNESS
ADJUSTING BOLT
EVAPORATOR
ICE THICKNESS
ADJUSTING BOLT
EVAPORATOR
POWER SWITCH
DISPLAY LAMP
POWER SWITCH
[ IM/WM-0460-AC/AH/WC/WH,
IM/WM-0460-AC/AH(115V),
PROXIMITY SENSOR
PUMP MOTOR
FLOATER
DRAIN PLUG
[ IM/WM-1100-AC/AH/WC/WH,
DRAIN SWITCH
PROXIMITY SENSOR
PUMP MOTOR
FLOATER
DRAIN PLUG
IM/WM-0460-AC/AH/WC/WH-22,
IM/WM-0680-AC/AH/WC/WH ]
IM-1100-RC/RH ]
30
※
Cleaning the condenser (per week): Air
-cooled model
Use a (portable) vacuum cleaner to remove any dust from the condenser panel surface.