![icetro ID-0450-AN Installation & Service Manual Download Page 42](http://html2.mh-extra.com/html/icetro/id-0450-an/id-0450-an_installation-and-service-manual_3403534042.webp)
Cleaning Procedure
Allow the cleaning solution
to sit for 10 minutes and
then turn ICE-OFF-WASH
switch to WASH.
The auger will rotate for 1
minute and then drain water
for 30 seconds 3 times.
Once the WASH cycle stops,
perform a FORCED DRAIN
to drain any remaining
water from the reservoir.
Return the ICE-OFF-WASH
switch back to ICE.
<! Caution !>
Remove all ice from the
dispenser and perform a
FORCED DRAIN to drain all
water from the reservoir.
Add cleaning solution
mixture through the
chemical funnel.
The auger will rotate for 5
minutes and then the water
reservoir will drain for 1
minute.
Washing Solution Mixing Method:
Mix ~ 8oz of NICKEL SAFE ICE
MACHINE CLEANER with 1gal of
warm water and place it in the
water reservoir.
●
Do not use ammonia-based products as they may cause damage to the personnel or ice machine itself.
●
Cleaning and sanitizing must be conducted in accordance with the instructions in the user manual.
●
Always wear protective gloves and goggles to prevent skin or eyes from coming into contact with the cleaning solution.
●
Do not use ice made with the cleaning or sanitizing solution. Make sure that no cleaning solution is left on any part of
the ice maker and the ice hopper.
Steps to use the WASH cycle:
42
Summary of Contents for ID-0450-AN
Page 1: ...ID 0450 AN INSTALL SERVICE MANUAL...
Page 2: ...ID 0450 Specs 2...
Page 3: ...ID 0450 Specs 3...
Page 17: ...Wiring Diagram 17...
Page 43: ...Parts Breakdown ID 0450 43...
Page 44: ...Parts Breakdown ID 0450 44...
Page 45: ...Parts Breakdown ID 0450 45...
Page 46: ...Parts Breakdown ID 0450 46...
Page 47: ...Parts Breakdown ID 0450 47...
Page 48: ...Parts Breakdown ID 0450 48...
Page 49: ...Thank You 1 15 2022...