13
13
Remove bricks and install wall box.
For homes under construction, install wall box as brickwork is going up.
Note: For M200 model, use Metal Wall Bracket Part Number: 100975 or construct a suitable timber frame.
Wall Box for Master Station – Cavity Brick Wall
Pull the cables through the wall box.
Lay the master face down on the bubble wrap provided in the packaging.
Fit all the terminal blocks to the terminal headers on the rear of the master.
Terminate the wiring as per the following MASTER TERMINATIONS section.
Separate the back housing from the master front
For the M250, the bottom latches on each side of the plastic front will need to be released
For the M200, the bottom of the plastic front can be pulled away from the bottom of the plastic
back.
Fit the back housing into the wall and secure using the 6G x 1½” screws provided or other
appropriate screws (depending on the wall box arrangement being used).
Hang the master front from the top of the back housing.
Push the bottom of the plastic front clipping it into the plastic back.
Ensure all the internal wiring of the master remains clear of the mating parts
For the M250, be sure to press and correctly align the plastic clips at the bottom of the back housing as the front is
pushed into position
.
Summary of Contents for System One M200