GB
12
3.
On
D201 and D310 Storage Bin
inspect
its top mounting gasket which should be flat with
no wrinkles, to provide a good sealing when the
Top Cover is installed on top of it.
4.
Place the NKF201-NKF310 Top Cover on
top of Storage bin using care not to wrinkle or
tear the gasket.
5.
On the D500 and D700 Storage Bin
unloose the screws securing the S.S. Top
Cover to the storage bin and remove it.
6.
Lay out on the bin top the plan of the ice
machine as it will be located on the bin and cut an
opening in the bin top for the ice drop area; cover
the edges of the opening with vinyl tape.
7.
Install the gasket-on the bin top-around ice
drop opening of the bin top; apply sealant along
the inside of the gasket.
8.
Position and install the four aluminium front
to rear stiffeners (U shaped) paying attention to
the guideline shown on the drawing.
NOTE
. Bin wall gasket must be cut to clear
the stiffener ends as shown on drawing.
Do not put any stiffeners crossing the ice
drop opening.
9.
Install the bin top in its position onto the bin
top by:
- place the rear side of top against rear edge
of the bin
- lower the front of the top onto the stiffeners
- re-fit the screws previously removed as
per step 5
10. Install the Modular Flaker or Superflaker
onto the Top Cover of storage bin pay attention
to match the ice chute with the Bin Top opening.
Installation of lift door catch (D500)
On the Storage Bin D500 when the ice maker
is installed flush with the bin front it is required to
mount the lift door catch as detailed herebelow.
1.
Open all the way the lift door in the upright
position then place the door catch on the front
face of the ice maker and tape it in place.
2.
Lay carefully down the bin on its back to
protect the finish and remove the bolts holding
the shipping skid to the bin.
3.
Screw-in the legs into the corresponding
tapped holes in the bin bottom and tighten to seat
the legs well against the bin bottom.
4.
Connect the water drain line to the 1" female
drain fitting located in the bottom of the bin.
CAUTIONS. Avoid excessive tightening
force when connecting to this fitting.
Do not apply excessive heat if any
sweating of the fittings is necessary. Heat
conduction through the metal may melt
the threads in the plastic drain.
5.
On
model D700
only insert the longer
side of each plastic inspection window in the
upper track of the corresponding opening and
push it to force the window to enter into its seat.
C.
LOCATION AND LEVELLING
1.
Position the storage bin in the selected
permanent location.
Criteria for selection of location include:
a) Minimum room temperature 10
°
C (50
°
F)
and maximum room temperature 40
°
C (100
°
F).
b) Water inlet temperatures: minimum 5
°
C
(40
°
F) and maximum 35
°
C (90
°
F).
c) Well ventilated location for air cooled
models (clean the air cooled condenser at
frequent intervals).
d) Service access: adequate space must
be left for all service connections through the rear
of the ice maker. A minimum clearance of 15 cm
(6") must be left at the sides of the unit for routing
cooling air drawn into and exhausted out of the
compartment to maintain proper condensing
operation of air cooled models.
2.
Level the Storage Bin Assy in both the left
to right and front to rear directions by means of
the adjustable legs.
STIFFENER
CUT GASKET HERE
BIN WALL GAKET
TOP SHELL
WARNING. This Modular Flaker and
Superflaker is designed for indoor
installation only. Extended periods of
operation at temperature exceeding the
following limitations will constitute
misuse under the terms of the ICEMATIC
Manufacturer’s Limited Warranty resulting
in LOSS of warranty coverage.
Summary of Contents for F 80 C