Rev AA
How to Configure the LPA
5-8
ICE Vulcan Service Manual
As such, these installation parameters are set through a configuration programme called
CLARiTY Configuration Manager.
The CLARiTY Configuration Manager (Figure 5-2) is a PC software program, that provides the
following basic features:
•
Setting of the LPA variables
•
Saving/retrieving a set of variable values to a PC file for later/ repeated use
•
Downloading a set of variables to the LPA's CLARiTY user interface for non-volatile
(permanent) memory storage in the LPA
•
Uploading a set of variables from the LPA for review/comparison/ modification
•
Updating the system software
•
Saving/retrieving language files
•
Saving/retrieving job, font, and graphics files
•
Snapshot of CLARiTY screens
Figure 5-2: CLARiTY Configuration Manager
As a result, the CLARiTY user interface retains the availability of a small number of operating
variables for the user to change.
It also provides an increased level of LPA system integrity, because the configuration
variables cannot be accessed from the LPA itself, but from a connected PC.
If the LPA is installed to run in a standalone mode (i.e., the LPA is not connected to network),
the PC is only linked briefly (via the RS232 serial or ethernet port) for the period of
upload/download of the variables (a few seconds). The PC would then be removed.
Summary of Contents for vulcan
Page 1: ...ICEVulcanServiceManual Vulcan Service Manual ...
Page 20: ...Equipment Safety Guidelines 2 5 ICEVulcan ServiceManual manual ...
Page 33: ...Labeller 3 8 ICEVulcan ServiceManual Figure 3 9 Dancer Arm Sensor PCB ...
Page 60: ...Installing the Label Applicator 4 13 ICEVulcan ServiceManual place Use an adjustable wrench ...
Page 168: ...Rev AA Printhead Assembly 7 20 ICEVulcan ServiceManual Table 7 31 Printhead Cable Guide ...
Page 173: ...Rev AA Printhead Assembly 7 23 ICEVulcan ServiceManual Table 7 39 Ribbon Drive Motor ...
Page 235: ...C 2 Main Board Test Points Rev AA ...