Rev AA
6-3
E3019
‘Unprinted Pack’ - Substrate speed fell below 40mm/s
for too long to print last pack.
Fault
E3020
‘Incorrect Reel Size’
Fault
E3021
‘Print Cycle Error’ - Note the values in Tools>diagnos-
tics>printhead>states>captured states and report.
Possible printer PCB or motor fault
Fault
E3024
‘24 Volt Error’ - The 24 volts supply is not in the work-
ing range. Power the printer OFF and ON to try and
clear the fault. If the problem persists, call your main-
tenance engineer or local service representative.
Fault
E3025
‘Printer Ambient Temperature’ - The internal ambient
temperature of the printer is outside its recommended
operating range. Touch the Clear button below to
clear this warning.
Warning
E3026
‘External Error’ - The operation of the printer has been
suspended by the control system. If the Clear button
is available below, you may touch it to clear this error
and resume printing.
Fault
E1100
‘Invalid Job File (Bad Field Reference)’ - Source field
reference incorrect - correct in CLARiSOFT
Warning
E1101
‘Invalid Job File (Missing Data Source Field)' - Job file
missing a data field - correct in CLARiSOFT
Warning
E1102
‘Invalid Job File (Duplicate Named Fields)’ - Field
names have been duplicated in Job File - correct in
CLARiSOFT
Warning
E1000
‘Image Update Failure’ - CLARiTY is unable to update
the image before receiving the next print signal since
the products are too close to each other.
Fault
E1001
‘Count Limit Reached’ - One or more fields in the
image design has reached the allocated end value.
Fault
E1002
‘Abort (Operation Aborted)’ - 'The operation of the
printer has been stopped by the host control system.
Fault
Error
No
Report on CLARiTY Operator Interface
Status
Table 6-1: List of Faults and Warnings
ICE
P
egasus
Service Manual