ICAN
July
2016
5
U
V
W
U
V
W
3-Phase Stepper Motor Drive
3MR8
To change the direction of motor, customers only need to change the line sequence of one of U V W
phases.
Star connection and triangular connection are available for 3 phase motors. Star connection is for low
speed occasions and triangular connection is for high speed occasions.
Star connection
Triangular connection
■
Connecting the motor