Maintenance Instructions
Troubleshooting
No Restriction Reading
Possible Causes
How To Check
Plugged fitting or vacuum line
Apply vacuum to gauge until locked up at RED zone. Reconnect line and hold in reset button.
Indicator will fully return unless line or fitting is plugged. A slow return is normal due to safety
filter in fitting.
Leak in vacuum line
Apply vacuum to gauge until locked up at RED zone. Reconnect gauge and close end of line air tight.
Hold in reset button. Indicator will drop slightly and then not move unless vacuum line has a leak.
Leak in gauge
Repeat above except close gauge connection airtight.
Air cleaner element split open
Visually inspect element.