Appendix B. Boot code display error codes
The boot code display area of the light path diagnostics panel provides an error
code that indicates the point at which the system stopped during the boot block
and POST. A boot code is either a byte or a word value that is produced by UEFI.
This display will provide error codes in the event of a microprocessor error or a
power fault. In addition to the IMM log, the codes can provide suggested
components to be replaced.
The following is an illustration show the boot code display area on the light path
diagnostics panel:
Light Path
Diagnostics
The following table lists the error codes that might display in the boot code
display area that is associated with the integrated voltage regulator power faults or
microprocessor failure events. Follow the action plan listed for the corresponding
IMM events listed in this table to solve the problem. See the Appendix D,
“Integrated management module II (IMM2) error messages,” on page 349 for the
corresponding IMM event ID and action plan to follow and correct the problem.
Table 28. System power faults
Boot
code
Message
Potential defective
component
Corresponding
IMM Event ID
Corresponding IMM
log message
01
5V_PGOOD
System Board
80070603-0701ffff
Sensor System VRD has
transitioned to
non-recoverable.
02
0_8VAUX_PGOOD
10G-T Card
80070603-0B01ffff
Sensor 10Gb-T VRD has
transitioned to
non-recoverable.
03
ENET_1_0VAUX_PGOOD
System Board
80070603-0701ffff
Sensor 10Gb-T VRD has
transitioned to
non-recoverable.
04
1_1V_PGOOD
System Board
80070603-0701ffff
Sensor MainBrd VRD
has transitioned to
non-recoverable.
© Copyright IBM Corp. 2012
317
Summary of Contents for x3750 M4
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...