Power
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
power-control
button
does
not
work
(the
server
does
not
start).
Note:
The
power-control
button
will
not
function
until
20
seconds
after
the
server
has
been
connected
to
ac
power.
1.
Make
sure
that
the
power-control
button
is
working
correctly:
a.
Disconnect
the
server
power
cords.
b.
Reconnect
the
power
cords.
c.
(Trained
service
technician
only)
Reseat
the
operator
information
panel
cables,
and
then
repeat
steps
1a
and
1b.
v
(Trained
service
technician
only)
If
the
server
starts,
reseat
the
operator
information
panel.
If
the
problem
remains,
replace
the
operator
information
panel.
2.
Make
sure
that:
v
The
power
cords
are
correctly
connected
to
the
server
and
to
a
working
electrical
outlet.
v
The
type
of
memory
that
is
installed
is
correct.
v
The
DIMM
is
fully
seated.
v
The
LEDs
on
the
power
supply
do
not
indicate
a
problem.
v
The
microprocessors
are
installed
in
the
correct
sequence.
3.
Reseat
the
following
components:
a.
DIMMs
b.
(Trained
service
technician
only)
Power
switch
connector
c.
(Trained
service
technician
only)
Power
backplane
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
Power
switch
connector
c.
(Trained
service
technician
only)
Power
backplane
d.
(Trained
service
technician
only)
System
board
5.
If
you
just
installed
an
optional
device,
remove
it,
and
restart
the
server.
If
the
server
now
starts,
you
might
have
installed
more
devices
than
the
power
supply
supports.
6.
See
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x
Documentation
CD.
The
server
does
not
turn
off.
1.
Determine
whether
you
are
using
an
Advanced
Configuration
and
Power
Interface
(ACPI)
or
a
non-ACPI
operating
system.
If
you
are
using
a
non-ACPI
operating
system,
complete
the
following
steps:
a.
Press
Ctrl+Alt+Delete.
b.
Turn
off
the
server
by
pressing
the
power-control
button
for
5
seconds.
c.
Restart
the
server.
d.
If
the
server
fails
POST
and
the
power-control
button
does
not
work,
disconnect
the
power
cord
for
20
seconds;
then,
reconnect
the
power
cord
and
restart
the
server.
2.
If
the
problem
remains
or
if
you
are
using
an
ACPI-aware
operating
system,
suspect
the
System
board.
86
IBM
System
x3500
Type
7977:
Installation
Guide
Summary of Contents for x3500 - System - 7977
Page 3: ...IBM System x3500 Type 7977 Installation Guide...
Page 14: ...xii IBM System x3500 Type 7977 Installation Guide...
Page 48: ...34 IBM System x3500 Type 7977 Installation Guide...
Page 76: ...62 IBM System x3500 Type 7977 Installation Guide...
Page 118: ...104 IBM System x3500 Type 7977 Installation Guide...
Page 122: ...108 IBM System x3500 Type 7977 Installation Guide...
Page 123: ......
Page 124: ...Part Number 44R5218 Printed in USA 1P P N 44R5218...