See
the
Storage
Manager
client
documentation
for
information
on
setting
cache
memory
options.
The
RAID
controller
has
a
Cache
active
LED
that
displays
the
current
status
of
the
cache.
The
LED
is
on
if
there
is
data
in
the
cache,
and
it
is
off
if
there
is
no
data
in
the
cache.
If
caching
is
enabled
and
the
Cache
active
LED
never
comes
on
during
I/O
activity,
it
indicates
that
the
cache
memory
has
failed
or
the
battery
has
failed
(the
green
Battery
LED
will
be
off).
Note:
Always
use
the
Storage
Manager
client
to
check
your
cache
memory
settings
before
assuming
a
hardware
failure.
shows
the
location
of
the
Cache
active
LED
on
the
front
of
the
RAID
controller.
RAID
controller
cache
battery
Each
RAID
controller
contains
a
sealed,
rechargeable
4-volt
lead-acid
battery.
This
battery
provides
cache
backup
for
up
to
three
days
in
the
event
of
a
power
loss.
The
service
life
of
the
battery
is
three
years,
after
which
time
the
battery
must
be
replaced.
See
the
Storage
Manager
client
for
information
on
how
to
view
and
set
the
battery
expiration
date.
Each
RAID
controller
has
a
green
Battery
LED
on
the
back
that
indicates
the
battery
status,
as
follows:
v
The
LED
is
on
and
remains
steady
when
the
battery
is
fully
charged.
v
The
LED
flashes
when
the
battery
is
charging
or
performing
a
self-test.
v
The
LED
is
off
if
the
battery
or
the
battery
charger
has
failed.
The
battery
performs
a
self-test
at
startup
and
every
25
hours
thereafter
(during
which
time
the
Battery
LED
flashes).
If
necessary,
the
battery
begins
recharging
at
that
time.
If
the
battery
fails
the
self-test,
the
Battery
LED
turns
off,
indicating
a
battery
fault.
Data
caching
starts
after
the
battery
completes
the
startup
tests.
Cache
active
LED
f10ug036
Figure
53.
Cache
active
LED
Chapter
4.
Operating
the
storage
server
67
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......
Page 160: ... Part Number 24P8970 Printed in USA GC26 7641 00 1P P N 24P8970 ...