a.
Slide
the
RAID
controller
all
the
way
into
the
empty
slot.
b.
Close
both
levers
until
the
latch
locks
into
place.
21.
Install
the
SFPs
and
then
connect
the
fibre-channel
cables
to
their
original
locations.
22.
Turn
on
power
to
the
storage
server
and
attached
devices.
For
the
proper
power-on
sequence,
see
23.
Wait
approximately
one
minute
and
then
use
the
Storage
Manager
client
to
place
the
controller
in
online
state
(it
was
placed
offline
in
step
If
the
operation
fails,
repeat
the
command.
If
the
operation
fails
again,
reseat
the
controller
and
repeat
this
step.
Note:
It
might
take
15
minutes
to
a
few
hours
for
a
new
battery
to
become
fully
charged.
The
Storage
Manager
client
will
show
the
battery
as
failed
until
it
is
fully
charged.
Controller
caching
is
automatically
disabled
until
the
new
battery
becomes
fully
charged.
24.
Use
the
Storage
Manager
client
to
monitor
the
status
of
the
storage
server
and
to
reset
the
battery
age.
Note:
There
are
two
cache
batteries
in
the
unit
(one
for
each
controller).
Make
sure
that
you
reset
the
age
for
the
correct
battery.
Installing
SFPs
and
fiber-optic
cables
Each
RAID
controller
unit
has
two
host
ports
and
one
expansion
unit
port.
SFPs
are
inserted
into
the
ports,
and
then
fibre-channel
cables
are
connected
to
the
SFPs.
For
information
on
installing
SFPs
and
fiber-optic
cables,
see
Adding
a
FAStT
EXP100
to
an
existing
FAStT100
configuration
You
can
add
up
to
three
FAStT
EXP100
drive
enclosures
to
a
FAStT100
storage
server.
However,
you
do
not
need
to
configure
the
FAStT100
with
the
maximum
number
of
EXP100s
at
the
time
of
initial
installation.
You
can
add
additional
EXP100s
to
an
existing
FAStT100
configuration
(up
to
the
maximum
number
of
EXP100s
supported
in
a
drive
loop)
as
you
need
more
capacity.
f10ug033
Figure
70.
Installing
a
new
RAID
controller
Chapter
5.
Installing
and
replacing
components
91
Summary of Contents for totalstorage fastt100
Page 2: ......
Page 10: ...viii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 14: ...xii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 18: ...xvi IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 30: ...xxviii IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 68: ...38 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 86: ...56 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 124: ...94 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 132: ...102 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 134: ...104 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 138: ...108 IBM TotalStorage FAStT100 Storage Server Installation User s and Maintenance Guide ...
Page 159: ......