Table
12.
Storage
server
LEDs
(front)
LED
Color
Operating
states
1
Drive
active
Green
v
On
-
Normal
operation.
v
Flashing
-
The
drive
is
reading
or
writing
data.
v
Flashing
every
5
seconds
-
The
drive
has
not
spun
up
or
the
drive
is
bad.
v
Off
-
One
of
the
following
situations
has
occurred:
–
The
storage
server
has
no
power.
–
The
drive
is
not
properly
seated
in
the
storage
server.
Drive
fault
Amber
v
Off
-
Normal
operation.
v
Flashing
-
The
DS4000
Storage
Manager
client
is
locating
a
drive,
logical
drive,
or
storage
subsystem.
v
On
-
The
drive
has
failed,
or
a
user
failed
the
drive.
Power
Green
v
On
-
Normal
operation.
v
Off
-
One
of
the
following
situations
has
occurred:
–
The
storage
server
has
no
power.
–
Both
power
supplies
have
failed.
–
There
is
an
over-temperature
condition.
General
system
error
Amber
v
Off
-
Normal
operation.
v
On
-
A
storage
server
component
has
failed
2
.
1
Always
use
the
DS4000
Storage
Manager
client
to
identify
the
failure.
2
Not
all
component
failures
turn
on
this
LED.
For
more
information,
see
“Monitoring
status
through
software”
on
page
70.
Activity LED
Fault LED
General system
error LED
Power-on LED
Latch
Tray handle
f10ug053
Figure
57.
Storage
server
LEDs
(front)
72
IBM
TotalStorage
DS4100
Storage
Server:
Installation,
User’s,
and
Maintenance
Guide
Summary of Contents for TotalStorage DS4100
Page 1: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Page 2: ......
Page 3: ...IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide GC26 7712 00...
Page 10: ...viii IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 18: ...xvi IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 32: ...xxx IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 76: ...44 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 96: ...64 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 109: ...Battery LED f10ug037 Figure 61 Battery LED Chapter 4 Operating the storage server 77...
Page 110: ...78 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 150: ...118 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 152: ...120 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 156: ...124 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 172: ...140 IBM TotalStorage DS4100 Storage Server Installation User s and Maintenance Guide...
Page 179: ......
Page 180: ...Part Number 25R0314 Printed in USA GC26 7712 00 1P P N 25R0314...