background image

switch

 

port.

  

A

 

port

 

on

 

a

 

switch.

 

Switch

 

ports

 

can

 

be

 

expansion

 

ports

 

(E_ports),

 

fabric

 

ports

 

(F_ports),

 

or

 

fabric

 

loop

 

ports

 

(FL_ports).

 

SWL.

  

See

 

short

 

wavelength

.

 

synchronous

 

dynamic

 

random

 

access

 

memory

 

(SDRAM).

  

The

 

main

 

memory

 

for

 

the

 

switch.

 

Used

 

for

 

volatile

 

storage

 

during

 

switch

 

operation.

 

T

 

Tachyon.

  

A

 

type

 

of

 

host

 

bus

 

adapter.

 

target.

  

A

 

storage

 

device

 

on

 

a

 

Fibre

 

Channel

 

network.

 

See

 

also

 

initiator

.

 

TCP.

  

See

 

transmission

 

control

 

protocol

.

 

tenancy.

  

The

 

time

 

from

 

when

 

a

 

port

 

wins

 

arbitration

 

in

 

a

 

loop

 

until

 

the

 

same

 

port

 

returns

 

to

 

the

 

monitoring

 

state.

 

Also

 

referred

 

to

 

as

 

loop

 

tenancy.

 

terminal

 

serial

 

port.

  

The

 

lower

 

serial

 

port

 

on

 

the

 

control

 

processor

 

card

 

(CP

 

card)

 

of

 

the

 

director

 

switch.

 

This

 

port

 

sends

 

switch

 

information

 

messages

 

and

 

can

 

receive

 

commands.

 

Can

 

be

 

used

 

to

 

connect

 

the

 

CP

 

card

 

to

 

a

 

computer

 

terminal.

 

Has

 

an

 

RS–232

 

connector

 

wired

 

as

 

a

 

data

 

terminal

 

equipment

 

(DTE)

 

device,

 

and

 

can

 

be

 

connected

 

by

 

serial

 

cable

 

to

 

a

 

data

 

communications

 

equipment

 

(DCE)

 

device.

 

The

 

connector

 

pins

 

2

 

and

 

3

 

are

 

swapped

 

so

 

that

 

a

 

straight-through

 

cable

 

can

 

be

 

used

 

to

 

connect

 

to

 

a

 

terminal.

 

The

 

device

 

name

 

is

 

ttyS0.

 

Can

 

also

 

be

 

referred

 

to

 

as

 

the

 

console

 

port.

 

See

 

also

 

DCE

 

port,

 

DTE

 

port,

 

and

 

modem

 

serial

 

port

.

 

throughput.

  

The

 

rate

 

of

 

data

 

flow

 

achieved

 

within

 

a

 

cable,

 

link,

 

or

 

system.

 

Usually

 

measured

 

in

 

bits

 

per

 

second

 

(bps).

 

See

 

also

 

bandwidth

.

 

topology.

  

As

 

applies

 

to

 

fibre

 

channel,

 

the

 

configuration

 

of

 

the

 

Fibre

 

Channel

 

network

 

and

 

the

 

resulting

 

communication

 

paths

 

allowed.

 

translative

 

mode.

  

A

 

mode

 

in

 

which

 

private

 

devices

 

can

 

communicate

 

with

 

public

 

devices

 

across

 

the

 

fabric.

 

transmission

 

character.

  

A

 

10–bit

 

character

 

encoded

 

according

 

to

 

the

 

rules

 

of

 

the

 

8b/10b

 

algorithm.

 

Transmission

 

control

 

protocol

 

(TCP).

  

A

 

communications

 

protocol

 

used

 

in

 

the

 

Internet

 

and

 

in

 

any

 

network

 

that

 

follows

 

the

 

Internet

 

Engineering

 

Task

 

Force

 

(IETF)

 

standards

 

for

 

Internet

 

protocol.

 

transmission

 

word.

  

A

 

group

 

of

 

four

 

transmission

 

characters.

 

trap

 

(SNMP).

  

The

 

message

 

sent

 

by

 

a

 

simple

 

network

 

management

 

protocol

 

(SNMP)

 

agent

 

to

 

inform

 

the

 

SNMP

 

management

 

station

 

of

 

a

 

critical

 

error.

 

See

 

also

 

simple

 

network

 

management

 

protocol

.

 

tunneling.

  

A

 

technique

 

for

 

enabling

 

two

 

networks

 

to

 

treat

 

a

 

transport

 

network

 

as

 

though

 

it

 

were

 

a

 

single

 

communication

 

link

 

or

 

local

 

area

 

network

 

(LAN).

 

Tx.

  

Transmitted.

 

U

 

U.

  

Unit

 

of

 

measure

 

for

 

rack-mounted

 

equipment.

 

UART.

  

Universal

 

Asynchronous

 

Receiver

 

Transmitter.

 

UDP.

  

See

 

user

 

datagram

 

protocol

.

 

ULP.

  

See

 

upper-level

 

protocol

.

 

ULP_TOV.

  

See

 

upper-level

 

timeout

 

value

.

 

unicast.

  

The

 

transmission

 

of

 

data

 

from

 

a

 

single

 

source

 

to

 

a

 

single

 

destination.

 

See

 

also

 

broadcast

 

and

 

multicast

.

 

universal

 

port

 

(U_port).

  

A

 

switch

 

port

 

that

 

can

 

operate

 

as

 

a

 

generic

 

port

 

(G_port),

 

expansion

 

port

 

(E_port),

 

fabric

 

port

 

(F_port),

 

or

 

fabric

 

loop

 

port

 

(FL_port).

 

A

 

port

 

is

 

defined

 

as

 

a

 

U_port

 

when

 

it

 

is

 

not

 

connected

 

or

 

has

 

not

 

yet

 

assumed

 

a

 

specific

 

function

 

in

 

the

 

fabric.

 

U_port.

  

See

 

universal

 

port

.

 

upper-level

 

protocol

 

(ULP).

  

The

 

protocol

 

that

 

runs

 

on

 

top

 

of

 

Fibre

 

Channel.

 

Typical

 

upper-level

 

protocols

 

are

 

small

 

computer

 

system

 

interface

 

(SCSI),

 

Internet

 

protocol

 

(IP),

 

HIPPI,

 

and

 

IPI.

 

upper-level

 

timeout

 

value

 

(ULP_TOV).

  

The

 

minimum

 

time

 

that

 

a

 

small

 

computer

 

system

 

interface

 

(SCSI)

 

upper-level

 

protocol

 

(ULP)

 

process

 

waits

 

for

 

SCSI

 

status

 

before

 

initiating

 

ULP

 

recovery.

 

user

 

datagram

 

protocol

 

(UDP).

  

A

 

protocol

 

that

 

runs

 

on

 

top

 

of

 

Internet

 

protocol

 

(IP)

 

and

 

provides

 

port

 

multiplexing

 

for

 

upper-level

 

protocols.

 

user

 

flash.

  

See

 

compact

 

flash

.

 

V

 

VC.

  

See

 

virtual

 

circuit

.

 

VCCI.

  

Voluntary

 

Control

 

Council

 

for

 

Interference

 

virtual

 

circuit

 

(VC).

  

A

 

one-way

 

path

 

between

 

node

 

ports

 

(N_ports)

 

that

 

allows

 

fractional

 

bandwidth.

 

W

 

WAN.

  

See

 

wide

 

area

 

network

.

 

WDM.

  

Wave

®

 

division

 

multiplexing.

   

Glossary

 

55

Summary of Contents for TotalStorage 2109 M12

Page 1: ...l M12 and Model M14 User s Guide GC26 7636 00 Read Before Using This product contains software that is licensed under written license agreements Your use of such software is subject to the license agr...

Page 2: ......

Page 3: ...IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide GC26 7636 00...

Page 4: ...IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states or regions do not allo...

Page 5: ...ent xvii Model M12 and M14 library xvii Related documents xvii Web sites xviii Getting software updates xviii Getting help xix How to send your comments xix Chapter 1 Introduction 1 Product overview 1...

Page 6: ...28 16 port card specifications 28 CP card specifications 29 Facility specifications 31 Power specifications 31 Environmental requirements 32 General specifications 33 Regulatory specifications 34 Appe...

Page 7: ...Index 57 Contents v...

Page 8: ...vi IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 9: ...1 Port side of the 2109 Model M12 3 2 Port side of the 2109 Model M14 4 3 Blower non port side of the M12 and M14 5 4 M12 16 port card port side 13 5 M14 16 port card port side 14 Copyright IBM Corp 2...

Page 10: ...viii IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 11: ...f the Model M12 and Model M14 27 7 Component weights 27 8 2109 Model C36 with Model M12 or M14 specifications 28 9 Memory specifications 29 10 Battery specifications 29 11 Terminal serial port pinouts...

Page 12: ...x IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 13: ...e the following examples of danger and caution notices for the location of the ID number Attention Inspections installations and service procedures are for trained service personnel only While the typ...

Page 14: ...ipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructe...

Page 15: ...ly hazardous to people because of some existing condition A caution notice can be accompanied by different symbols as in the examples below If the symbol is It means A hazardous electrical condition w...

Page 16: ...ice guides The procedures contained in those publications are for trained service personnel only Laser safety This equipment contains Class 1 laser products and complies with FDA radiation Performance...

Page 17: ...fire marshal or a local building inspector or both should be consulted in selecting a fire suppression system that provides the correct level of coverage and protection IBM designs and manufactures e...

Page 18: ...xvi IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 19: ...information related to this product v IBM TotalStorage SAN Switch 2109 Model M14 Installation and Service Guide GC26 7631 v IBM TotalStorage SAN Switch 2109 Model M12 Installation and Service Guide GC...

Page 20: ...following Web site http www ibm com servers storage support san To get specific details about models and firmware that the switch supports see the following Web site http www storage ibm com ibmsan Fo...

Page 21: ...te and high quality information If you have comments or suggestions for improving this document you can send us comments electronically by using the following addresses v Internet starpubs us ibm com...

Page 22: ...xx IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 23: ...availability topology v The switches support 1 Gbps and 2 Gbps auto sensing fibre channel ports Trunking technology groups up to four ports together to create high performance 8 Gbps ISL trunks betwee...

Page 24: ...s at distances greater than 10 km 6 21 mi using various methods The switch leverages the current dense wavelength division multiplexing DWDM certification and is certified to interoperate with equipme...

Page 25: ...basic features are shown in Figure 1 and Figure 2 on page 4 and are described in sections below RS 232 RS 232 Link 10 100 Mb s Link 10 100 Mb s Slot 1 2 3 4 5 6 7 8 9 10 Exhaust Vent Power Supply 4 P...

Page 26: ...Switch AC Power Connector for Power Supply 1 3 for Power Supply 2 4 AC Power Switch AC Power Connector Grounding Strap Connector Power Supply Filler Panel Card Slot Filler Panel Power Supply 2 Power...

Page 27: ...aaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaa aaaaaaaaaaa...

Page 28: ...reliability v Power on self test POST v An error detection and correction mechanism to protect all data in the switch v Error detection and fault isolation such as cyclic redundancy checking CRC parit...

Page 29: ...4 port fibre channel switches in a single chassis or a 128 port fibre channel switch M14 only Two CP blade assemblies are installed in each chassis to provide automatic failover protection A single ac...

Page 30: ...es are numbered from 1 4 from bottom to top v Blowers are numbered from 1 3 from left to right Rack mounting The mechanical design of the M12 and M14 allows rack mounting with either the cable side or...

Page 31: ...e contains multiple serial numbers for identifying the chassis back plane and the WWN card itself As an alternative system status indicator this card consolidates the status of all modular components...

Page 32: ...10 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 33: ...rotects from any input voltage static or dynamic from zero volts to its operating ranges It recovers to normal operation when it returns to its operating range Power distribution strategy All power fo...

Page 34: ...d then applies power If sufficient power is not available for example if only one of the possible four power supplies are installed the system does not allow more than four switch blade assemblies plu...

Page 35: ...tch M14 only Each 64 port switch uses four 16 port blade assemblies The blade assemblies for the M12 and M14 are the same form factor but have observable differences in the ejectors the ON OFF switche...

Page 36: ...atically mirrored to the standby CP card The new CP card automatically assumes the IP address and host name assigned to the slot If the new CP card does not have the same firmware as the active CP car...

Page 37: ...he CP blade assembly features the following v SDRAM controller that is built into the PPC405 with error correction support at 100 MHz v SDRAM that supports 128 Mb configuration v Socket PLCC32 boot fl...

Page 38: ...of each blade assembly Switch blade assembly Up to eight 16 port switch blade assembly can be installed in the chassis of the M12 or M14 Each switch blade assembly provides 16 external fibre channel...

Page 39: ...following are the dimensions of the switch blade assembly v 42 06 cm 16 56 in high v 29 74 cm 11 71 in wide v 3 58 cm 1 41 in deep Each switch blade assembly is connected to the backplane through high...

Page 40: ...18 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 41: ...ch CP blade assembly and each power supply module The blowers which are accessible on the noncable side also have LEDs that indicate their status Cable side LEDs Table 4 describes the appearance of th...

Page 42: ...placement is necessary Noncable side LEDs Table 5 describes the appearance of the LEDs on the noncable side of the system Table 5 Noncable side LEDs LED location Indication Blower v Green indicates th...

Page 43: ...Advanced Zoning Segments a fabric into virtual private SANs See the following documents for more information about Fabric Watch Fabric Manager and Web Tools v Brocade Fabric Watch User s Guide v Broca...

Page 44: ...he superior security of hardware enforced zoning configurations even if one or more hosts get moved to attach through different switch ports The same frame filtering technology that enables hardware e...

Page 45: ...ts Layer SSL The SSL security protocol provides data encryption server authentication message integrity and optional client authentication for a TCP IP connection Because SSL is built into all major b...

Page 46: ...24 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 47: ...stories to determine MTBF For more information about how to perform these tasks see the Brocade Fabric OS Reference The FRUs for the M12 and M14 include v 16 port fibre channel switch module blade v C...

Page 48: ...26 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 49: ...es plug into internal blind mate connectors when installed in the chassis v Two ac power inlet connectors with ac power switches power panel v A WWN card and bezel v Three blower assemblies for forced...

Page 50: ...3 mm 24 5 in EIA units 36 EIA units Weight Cabinet with two 2109 Model M12 switches 816 kg 1795 lb Cabinet with two 2109 Model M14 switches 780 kg 1720 lb 16 port card specifications The ports in the...

Page 51: ...ns Table 10 Battery specifications Type Specification Rayovac BR1225 3 0 volt 50 mAh CAUTION Only trained service personnel may replace this battery The battery contains lithium To avoid possible expl...

Page 52: ...ver the serial port is not being used Use the modem serial port to attach a modem to each CP card The M12 and M14 detects modems only during the power on or restart sequences and automatically initial...

Page 53: ...d distributed name server DNS It is electro magnetic compatibility EMC compliant The power supplies are universal and capable of functioning worldwide without using voltage jumpers or switches They me...

Page 54: ...output power 1000 watts Maximum ac inrush current per power cord 40 amps peak Ride through The supply outputs remain within specified regulation for a minimum of 20 msec after the ac mains are discon...

Page 55: ...C compatibility EmissionsAn operating 2109 Model C36 with Model M12 or M14 conforms to the EMI radiation levels specified by the following regulations v FCC Rules and Regulations Part 15B Class A leve...

Page 56: ...t cover and rear cover with acoustic baffle declared sound power is LwAd 7 5 B average bystander sound pressure is LpA 59 dBA Routing capacity A minimum aggregate routing capacity of four million fram...

Page 57: ...94 A11 2 EN 61000 4 2 Severity Level 3 for Electro Static Discharge EN 61000 4 3 Severity Level 3 for Radiated Fields EN 61000 4 4 Severity Level 3 for Electrical Fast Transients EN 61000 4 5 Severity...

Page 58: ...36 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 59: ...ower configuration comply with EMI levels specified by the following regulations v Electromagnetic Compatibility EMC Directive 89 336 EEC and the Complementary Directives 92 31 EEC and 93 68 EEC v Low...

Page 60: ...000 4 4 Severity Level 3 for EFT Burst v EN 61000 4 5 Severity Level 3 for Surge Voltage v EN 61000 4 11 Power Sag Dip and Variations 38 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s...

Page 61: ...consistent with local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WA...

Page 62: ...ause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter...

Page 63: ...romagnetische Vertr glichkeit von Ger ten EMVG vom 18 September 1998 bzw der EMC EG Richtlinie 89 336 Dieses Ger t ist berechtigt in bereinstimmung mit dem Deutschen EMVG das EG Konformit tszeichen CE...

Page 64: ...Taiwan Class A Electronic Emission Statement Japan VCCI Class A ITE Electronic Emission Statement 42 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 65: ...Can also refer to a list of the read write access of a particular community string See also device connection controls account level switches Switches that have four login accounts into the operating...

Page 66: ...s with diskette drives hard disk drives and the keyboard BB_credit See buffer to buffer credit beacon When all the port light emitting diodes LEDs on a switch are set to flash from one side of the swi...

Page 67: ...racter alignment within a data stream See also K28 5 command line interface CLI Interface that depends entirely on the use of commands such as through Telnet or simple network management protocol SNMP...

Page 68: ...lue between 1 239 DRAM See dynamic random access memory DTE port See data terminal equipment DTE port dual fabric Two identical fabrics that allow redundancy in the event that one fabric fails Use a d...

Page 69: ...switches hosts and devices A fabric is an active intelligent nonshared interconnect scheme for nodes Fabric Access Allows the application to control the fabric directly for functions such as discover...

Page 70: ...l connections at data rates from 265 Mbps up to 4 Gbps Fibre Channel service FS A service that is defined by Fibre Channel standards and exists at a well known address For example the Simple Name Serv...

Page 71: ...s heartbeat is typically carried over a dedicated network for clustering traffic In cases of a problem for example a software crash on the operational server or a hardware component failure a heartbea...

Page 72: ...must be kept secret L LAN See local area network latency The period of time required to transmit a frame from the time it is sent until it arrives LED See light emitting diode light emitting diode LED...

Page 73: ...n modem cable Consists of a DB 9 connector wired as an RS 232 device and can be connected by serial cable to a data communications equipment DCE device A Hayes compatible modem or Hayes emulation is r...

Page 74: ...luggable SFP can be inserted port card A Fibre Channel card that contains optical or copper port interfaces and acts like a switch module See also 16 port card port login PLOGI The port to port login...

Page 75: ...ation a process also known as tunneling such as fibre channel over asynchronous transfer mode ATM or fibre channel over Internet protocol IP remote procedure call RPC A facility that a client uses to...

Page 76: ...ame server SNS A switch service that stores names addresses and attributes for up to 15 minutes and provides them as required to other devices in the fabric SNS is defined by Fibre Channel standards a...

Page 77: ...s protocol used in the Internet and in any network that follows the Internet Engineering Task Force IETF standards for Internet protocol transmission word A group of four transmission characters trap...

Page 78: ...hosts within the same zone have access permission to others in the zone but are not visible to any outside the zone See also zoning zone alias An alias for a set of port numbers or worldwide names WW...

Page 79: ...n xi example xi dc outputs 11 design overview 3 switch blade assembly 17 diagnostic tests 19 dimensions of the switch 27 director of licensing address 39 disposal product xv E edition notice ii electr...

Page 80: ...pecifications of the switch 31 product disposal xv overview 1 recycling xv specifications 28 R rack mounting 8 reader comment form processing xix recycling products xv regulatory compliance 37 specifi...

Page 81: ...ession xv power distribution 11 status indicators 19 T take back program product xv terminal serial port specifications 29 terminators for optical ports xiv tests diagnostic 19 throughput high speed f...

Page 82: ...60 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Page 83: ...is book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Applicable...

Page 84: ...Development Department GZW 9000 South Rita Road Tucson AZ 85744 0001 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 85: ......

Page 86: ...Part Number 22R0919 Printed in USA GC26 7636 00 1P P N 22R0919...

Page 87: ...Spine information IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...

Reviews: