Table
13.
Power
specifications
(continued)
Specification
Value
Heat
output
(BTU
rating)
v
64
ports:
1080
watts,
3690
BTU
per
hour
v
128
ports
:
1960
watts,
6700
BTU
per
hour
Maximum
inrush
current
per
power
cord
40
amps
Peak
Input
line
protection
Thermal
circuit
breaker
Power
supply
dimensions
6.96
cm
(2.74
in.)
wide,
12.34
cm
(4.86
in.)
high,
34.29
cm
(13.50
in.)
long
Table
14
lists
the
power
specifications
for
the
2109
Model
C36
with
Model
M14
Table
14.
Power
specifications
Specification
Value
Input
voltage
A
fully
loaded
switch
requires
a
maximum
of
750
Volt-Amps
This
results
in
a
main
current
of
3.2
amps
at
240
V
ac
line
voltage
or
3.6
amps
at
208
V
ac
line
voltage.
The
rated
ac
input
range
is
180
to
264
V
ac.
Supported
power
range
200–240
V
ac,
single
phase
Input
frequency
range
47–63
Hz
Power
supplies
(each)
Output
voltages:
48
V
at
20
amps;
12
V
at
4
amps
Maximum
output
power:
1000
watts
Maximum
ac
inrush
current
per
power
cord
40
amps,
peak
Ride
through
The
supply
outputs
remain
within
specified
regulation
for
a
minimum
of
20
msec
after
the
ac
mains
are
disconnected.
Under
voltage
protection
The
M14
power
supply
self-protects
from
any
input
voltage,
static
or
dynamic,
from
zero
volts
to
its
operating
ranges.
It
recovers
to
normal
operation
upon
returning
to
its
operating
range.
Environmental
requirements
Table
15
lists
the
environmental
operating
ranges
for
the
2109
Model
C36
with
Model
M12
or
M14.
The
requirements
for
non-operating
conditions
are
also
provided
for
acceptable
storage
and
transportation
environments.
Table
15.
Environmental
requirements
Condition
Acceptable
range
during
operation
Acceptable
range
during
nonoperation
Temperature
(See
Note)
10°—40°C
(50°—104°F)
10°—52°C
(50°—126°F)
Humidity
20%—80%
RH
noncondensing,
at
40°C
0%—90%
RH
noncondensing,
at
40°C
Altitude
0—3
km
(0—10
000
ft)
above
sea
level
0—12
km
(0—39
370
ft)
above
sea
level
32
IBM
TotalStorage
SAN
Switch:
2109
Model
M12
and
Model
M14
User’s
Guide
Summary of Contents for TotalStorage 2109 M12
Page 2: ......
Page 3: ...IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide GC26 7636 00...
Page 7: ...Index 57 Contents v...
Page 8: ...vi IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 10: ...viii IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 12: ...x IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 18: ...xvi IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 22: ...xx IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 32: ...10 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 40: ...18 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 46: ...24 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 48: ...26 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 58: ...36 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 82: ...60 IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...
Page 85: ......
Page 86: ...Part Number 22R0919 Printed in USA GC26 7636 00 1P P N 22R0919...
Page 87: ...Spine information IBM TotalStorage SAN Switch 2109 Model M12 and Model M14 User s Guide...