3.
Locate the Clear CMOS/Recovery jumper on the system board. See
“Identifying parts on the system board” on page 55.
4.
If necessary, see “Installing adapters” on page 58 to remove any adapters that
impede access to the Clear CMOS/Recovery jumper.
5.
Move the jumper from the standard position (pins 1 and 2) to the
maintenance or configure position (pins 2 and 3).
6.
Replace the cover and connect the power cord. See “Replacing the cover and
connecting the cables”.
7.
Restart the computer, leave it on for approximately 10 seconds. Turn off the
computer by holding the power switch for approximately 5 seconds. The
computer will turn off.
8.
Repeat steps 2 through 4 on page 66.
9.
Move the jumper back to the standard (pins 1 and 2).
10.
Replace the cover and connect the power cord. See “Replacing the cover and
connecting the cables”.
Replacing the cover and connecting the cables
After working with options, you need to install any removed parts, replace the
cover, and reconnect any cables, including telephone lines and power cords. Also,
depending on the option that is installed, you might need to confirm the updated
information in the IBM Setup Utility program.
To replace the cover and connect cables to your computer:
1.
Ensure that all components have been reassembled correctly and that no tools
or loose screws are left inside your computer.
2.
Clear any cables that might impede the replacement of the cover.
3.
Position the cover on the chassis so that the guides on the top and bottom of
the cover engage the chassis and push the cover to the closed position. Insert
Chapter 3. Types 2296 and 8434
67
Summary of Contents for ThinkCentre A30 8198
Page 1: ...ThinkCentre User Guide Types 2296 8191 8198 8199 8316 8434...
Page 2: ......
Page 3: ...ThinkCentre User Guide Types 2296 8191 8198 8199 8316 8434...
Page 34: ...22 User Guide...
Page 108: ...96 User Guide...
Page 120: ...108 User Guide...
Page 122: ...110 User Guide...
Page 127: ......
Page 128: ...Part Number 74P2399 Printed in U S A 1P P N 74P2399...