Error
code
Description
Action
1805
PCI
option
ROM
checksum
error.
1.
Remove
the
failing
adapter.
2.
Reseat
each
adapter
(all
PCI
slots).
3.
Reseat
the
riser
card.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Each
adapter
b.
Riser
card
c.
(Trained
service
technician
only)
System
board
1810
PCI
error.
1.
Reseat
all
adapters.
2.
Reseat
the
riser
card.
3.
Remove
both
adapters
from
the
riser
card.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Riser
card
b.
(Trained
service
technician
only)
System
board
1962
A
hard
disk
drive
does
not
contain
a
valid
boot
sector.
1.
Make
sure
that
a
startable
operating
system
is
installed.
2.
Run
the
hard
disk
drive
diagnostic
tests.
3.
Reseat
the
following
components:
a.
Hard
disk
drive
b.
Hard
disk
drive
backplane
cable
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Cable
from
hard
disk
drive
backplane
to
system
board
b.
Hard
disk
drive
c.
Hard
disk
drive
backplane
d.
(Trained
service
technician
only)
System
board
8603
Pointing-device
error.
1.
Reseat
the
pointing
device.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Pointing
device
b.
(Trained
service
technician
only)
System
board
32
IBM
System
x3650
Type
7979
and
1914:
Problem
Determination
and
Service
Guide
Summary of Contents for System x3650 Type 7979
Page 1: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 104: ...86 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 180: ...162 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 193: ......
Page 194: ...Part Number 31R1705 Printed in USA 1P P N 31R1705...