v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
7979
and
1914
server,”
on
page
79
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System
event/error
log
message
Action
+1.8v
critical
under
voltage
fault
Information
only
The
system
real
time
clock
battery
is
no
longer
reliable.
Replace
the
battery.
+3.3v
critical
over
voltage
fault
1.
Remove
all
PCI
adapters.
2.
Reinstall
each
PCI
adapter,
one
at
a
time,
restarting
the
server
each
time,
to
isolate
a
defective
adapter.
Replace
any
defective
adapter.
3.
If
the
error
continues,
(trained
service
technician
only)
replace
the
system
board.
+3.3v
critical
under
voltage
fault
1.
Remove
all
PCI
adapters.
2.
Reinstall
each
PCI
adapter,
one
at
a
time,
restarting
the
server
each
time,
to
isolate
a
defective
adapter.
Replace
any
defective
adapter.
3.
If
the
error
continues,
(trained
service
technician
only)
replace
the
system
board.
3.3V
Bus
Fault
1.
Remove
all
PCI
adapters.
2.
Reinstall
each
PCI
adapter,
one
at
a
time,
restarting
the
server
each
time,
to
isolate
a
defective
adapter.
Replace
any
defective
adapter.
3.
If
the
error
continues,
(trained
service
technician
only)
replace
the
system
board.
Power
Good
Fault
1.
Reseat
the
power
supplies.
2.
If
the
error
continues,
replace
the
power
backplane.
VRM
1
Power
Good
Fault
1.
(Trained
service
technician
only)
Reseat
microprocessor
1.
2.
(Trained
service
technician
only)
Replace
microprocessor
1.
3.
(Trained
service
technician
only)
Replace
the
system
board.
VRM
2
Power
Good
Fault
1.
Reseat
the
VRM.
2.
(Trained
service
technician
only)
Reseat
microprocessor
2.
3.
Replace
the
VRM.
4.
(Trained
service
technician
only)
Replace
microprocessor
2.
5.
(Trained
service
technician
only)
Replace
the
system
board.
VRM
2
is
present
Information
only
VRM
2
is
not
present
If
microprocessor
2
is
installed,
install
or
replace
the
VRM.
Memory
Area
non-critical
over
temperature
warning
1.
Make
sure
that
the
fans
are
operating
and
are
not
obstructed.
2.
Make
sure
that
the
air
baffles
are
in
place
and
correctly
installed.
3.
Make
sure
that
the
server
cover
is
installed
and
fully
closed.
Chapter
2.
Diagnostics
71
Summary of Contents for System x3650 Type 7979
Page 1: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 8: ...vi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 18: ...xvi IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 104: ...86 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 180: ...162 IBM System x3650 Type 7979 and 1914 Problem Determination and Service Guide...
Page 193: ......
Page 194: ...Part Number 31R1705 Printed in USA 1P P N 31R1705...