22. Install the bezel (see “Installing the bezel” on page 49).
23. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Note:
To support Windows 2011 SBS on Brocade adapters need to use at least
3.0.0.0 driver package or later version.
Installing a microprocessor and heat sink
To install the microprocessor and heat sink, complete the following steps:
1. Touch the static-protective package that contains the microprocessor to any
unpainted metal surface on the server. Then, remove the microprocessor from
the package.
2. Remove the protective cover, tape, or label from the surface of the
microprocessor socket, if any is present.
3. Rotate the release lever on the microprocessor socket to the fully open
position.
Attention:
Make sure that the release lever on the microprocessor socket is
in the fully open position before you insert the microprocessor in the socket.
Failure to do so might result in permanent damage to the microprocessor,
microprocessor socket, and system board.
4. Carefully grasp the microprocessor and place the microprocessor into the
microprocessor socket.
Note:
To maintain correct orientation between the microprocessor and the
microprocessor socket during installation, observe the following information:
v
The microprocessor has two notches that are keyed to two tabs on the
sides of the socket.
v
A triangle-shaped indicator on one corner of the microprocessor points to a
45-degree angle on the system board.
v
Do not use excessive force when you press the microprocessor into the
socket.
5. Close the microprocessor bracket frame; then, close the microprocessor
retention latch and lock it securely in place.
44
System x3100 M4 Type 2582: Installation and User's Guide
Summary of Contents for System x3100 M4
Page 1: ...System x3100 M4 Type 2582 Installation and User s Guide...
Page 2: ......
Page 3: ...System x3100 M4 Type 2582 Installation and User s Guide...
Page 8: ...vi System x3100 M4 Type 2582 Installation and User s Guide...
Page 18: ...xvi System x3100 M4 Type 2582 Installation and User s Guide...
Page 90: ...72 System x3100 M4 Type 2582 Installation and User s Guide...
Page 100: ...82 System x3100 M4 Type 2582 Installation and User s Guide...
Page 106: ...88 System x3100 M4 Type 2582 Installation and User s Guide...
Page 107: ......
Page 108: ...Part Number 00D3167 Printed in USA 1P P N 00D3167...