Removing the power cord
To remove the power cord, complete the following steps.
Mounting
plate
Mounting
post
Plug
mount
M3
screws
Power
cord
Power
cord mounting
bracket
1. Read the safety information that begins on page vii and “Installation guidelines”
2. If the 2U chassis or 3U chassis is installed in an iDataPlex rack, remove the
chassis from the rack (see “Removing the 2U chassis from a Type 7825
iDataPlex rack” on page 123) or (see “Removing a 3U chassis from a Type
7825 iDataPlex rack” on page 129).
3. Unplug the power cord that you are working on from the PDU.
4. Use an M3 hex driver to remove the two screws from the rail and set them
aside.
5. Pull the mounting plate and power cord toward the front of the rack cabinet.
6. Separate the power cord from the mounting plate; then, set the mounting plate
aside.
7. If you are instructed to return the power cord, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
92
System x iDataPlex dx340 Types 6385, 6386, 6389, 7831, 7832, and 7834: Problem Determination and Service Guide